Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WENDELL W. WELLER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WENDELL W. WELLER in 1030 36TH AVE., E., ELLENTON, FL 34222 (NAICS 238160). OSHA activity number 344164553.

Watch Wendell W. Weller — free Get an email when a new federal OSHA severe-injury report for Wendell W. Weller is published. One employer, no account, unsubscribe in one click.
Establishment
WENDELL W. WELLER
Site address
1030 36TH AVE., E.
City
ELLENTON
State
FL
ZIP
34222
Mailing
1114 51ST STREET, W., BRADENTON, FL 34209
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:     a)  On or about July 15, 2019, employees were exposed to eye injuries while using Hitachi NV83A5 Pneumatic Nail Guns while installing waterproofing paper without wearing safety glasses.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) On or about July 15, 2019, employees without fall protection were exposed to falls, while conducting re-roofing activities approximately 9 feet from the ground, on a single story, 3:12 pitch residential roof.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1926.1053 B05 I

Serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $1705.00 · Current $1023.00 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:  a)  On or about July 15, 2019, employees conducting re-roofing activities using a Werner 16 foot extension ladder was not used in an adequate angle in that it was extended 12 feet and the distance between the foot of the ladder and the wall was 6.5 feet from the wall exposing them to a fall hazard.
Recent events (2)
  • — I (S) $1023
  • — Z (S) $1705

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344164553.