Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEATHER KNIGHT EXTERIORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEATHER KNIGHT EXTERIORS, INC. in 1400 W. ALGONQUIN, PALATINE, IL 60038 (NAICS 238160). OSHA activity number 344170501.

Watch Weather Knight Exteriors, INC. — free Get an email when a new federal OSHA severe-injury report for Weather Knight Exteriors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1400 W. ALGONQUIN
City
PALATINE
State
IL
ZIP
60038
Mailing
129 KNOBB HILL LANE, GURNEE, IL 60031
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $319.00 · Current $319.00
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated,.       Weather Knight Exteriors, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                    01a                                   09/30/2019  01                                    01b                                   09/30/2019  01                                    01c                                   09/30/2019  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $319

1926.501 B10

Serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system;      a) On or about July 22, 2019, employees were exposed to the hazard of falling approximately 17 feet while performing roofing work without the use of fall protection or a safety monitoring system.         In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3978

1926.502 F01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:      a) On or about July 22, 2019, warning lines were not erected around all sides of the roof work area.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.502 F02 II

Serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(2)(ii): Warning line systems were not rigged and supported in such a way that its lowest point (including sag) was not less than 34 inches from the walking/working surface:         a) On or about July 22, 2019, warning lines along the roof edge were not rigged and supported to prevent sagging below 34 inches.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

View WEATHER KNIGHT EXTERIORS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344170501.