Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRINITY OPERATING (USG), LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of TRINITY OPERATING (USG), LLC in OIL RIG SITE, TILDEN, TX 78072 (NAICS 213112). OSHA activity number 344172341.

Watch Trinity Operating (USG), LLC — free Get an email when a new federal OSHA severe-injury report for Trinity Operating (USG), LLC is published. One employer, no account, unsubscribe in one click.
Site address
OIL RIG SITE
City
TILDEN
State
TX
ZIP
78072
Mailing
700 UNIVERSE BLVD. LAW/JB, JUNO BEACH, FL 33408
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
200
Ownership type
A

8 citations on file for this inspection.

1910.147 C02 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(2)(ii): The employer's tagout energy control program procedures did not successfully comply with 29 CFR 1910.147(c)(3) and no lockout was provided for employee protection:    Employer does not have an adequate LO/TO program for employees working on the Trinity-Hayes A 1-7H production well, program did not address air compressor tied in to a natural gas line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.147 C04 II

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec(a):   Employees conducted maintenance on air compressors at the Trinity-Hayes A 1-7H and were not provided a energy control procedure specifically addressing LO/TO procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $13260.00
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    Employer did not provide a LO/TO procedure to isolate an air compressor connected to a gas line.
Recent events (2)
  • — I (S) $13260
  • — Z (S) $0

1910.147 F02 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:   JW Huges Excavation, Inc. and Trinity Operating did not exchange or inform each other LO/TO procedures prior to conducting maintenance on air compressors at the Trinity-Hayes A 1-7H site.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F02 II

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(2)(ii): The onsite employer did not ensure that his or her personnel understood and complied with restrictions and prohibitions of the outside employer's energy control procedures:    Employer did not ensure outside contractors were provided a copy of their energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft:    Employer did not revise or establish a procedure for employees who conducted work on air compressors connected to gas lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E02 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1910.1200(e)(2)(i): At a multi-employer workplace, the employer's hazard communication program did not include methods the employer used to provide other employers with on-site access to a material safety data sheet for each hazardous chemical the other employer(s)' employees may be exposed to while working:    Employer did not provided contractors at this worksite with MSDS or information concerning chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.1200 E02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $13260.00
29 CFR 1910.1200(e)(2)(ii): The employer's hazard communication program did not include methods the employer will use to inform the other employer(s) of any precautionary measures that need to be taken to protect employees during the workplace's normal operations and in foreseeable emergencies:    Employer hazard communication program did not include a method to inform other employers of potential hazards involving the air compressor at the Trinity-Hayes A 1-7H well site.    MODIFIED AVD FROM SETTLEMENT AGREEMENT:    The Employers hazard communication program did not include a method to inform other employers of potential hazards involving the air compressor which was connected to a gas line at the Trinity-Hayes A 1-7H
Recent events (2)
  • — I (S) $13260
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344172341.