OSHA Inspection: MARTINEZ METAL INSTALLATION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARTINEZ METAL INSTALLATION, LLC in 2990 PHILLIPS HIGHWAY, JACKSONVILLE, FL 32207 (NAICS 238130). OSHA activity number 344172531.

Watch Martinez Metal Installation, LLC — free Get an email when a new federal OSHA severe-injury report for Martinez Metal Installation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2990 PHILLIPS HIGHWAY
City
JACKSONVILLE
State
FL
ZIP
32207
Mailing
845 SW JONES TER, LAKE CITY, FL 32025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:   a. On July 22, 2019, on the 2:12 pitch roof, an employee installing metal decking was not protected from a 14 to 16 feet fall hazard by the use of a fall protection system.
Recent events (1)
  • — Z (S) $3978

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder:   a. On July 22, 2019, the portable ladder did not extend above the landing surface, exposing the employee to a 14 feet fall hazard.
Recent events (1)
  • — Z (S) $2842

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a. On July 22, 2019, an employee used the top step of a 12 feet portable ladder to hand materials to the foreman on the roof, exposing himself to a 12 feet fall hazard.