Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAVID FRIZZELL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAVID FRIZZELL in 404 EDINBURGH ROAD, DUBLIN, OH 43016 (NAICS 238320). OSHA activity number 344190483.

Watch David Frizzell — free Get an email when a new federal OSHA severe-injury report for David Frizzell is published. One employer, no account, unsubscribe in one click.
Establishment
DAVID FRIZZELL
Site address
404 EDINBURGH ROAD
City
DUBLIN
State
OH
ZIP
43016
Mailing
1189 WOODBROOK LANE, COLUMBUS, OH 43223
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $1989.00 Reduced
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.   a. Located at 404 Edinburgh Road in Dublin, Ohio: On or about July 30, 2019, the employer did not develop and implement safety and health programs to ensure hazards were identified and corrected onsite while employees were performing painting and fascia work.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1926.416 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2842.00 · Current $1421.00 Reduced
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.  a. Located at 404 Edinburgh Road in Dublin, Ohio: On or about July 30, 2019, employees were performing fascia work with the use of an aluminum extension ladder onsite. The employer did not ensure that the ladder was maintained a safe distance from an energized overhead 7,620 volt powerline, thereby exposing employees to an electrocution hazard.
Recent events (2)
  • — I (S) $1421
  • — Z (S) $2842

1926.416 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(a)(3): Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.   a. Located at 404 Edinburgh Road in Dublin, Ohio: On or about July 30, 2019, the employer did not assess the worksite prior to the beginning of work to ensure that no employee or object could come in contact with energized overhead 7,620 volt powerlines located adjacent the rear side of the building. Employees using an aluminum extension ladder at the rear of the building were exposed to an electrocution hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B12

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.951(c)(1) of this part.   a. Located at 404 Edinburgh Road in Dublin, Ohio: On or about July 30, 2019, employees were using an aluminum extension ladder near energized overhead 7,620 volt powerlines located adjacent the rear side of the building. The siderails of the ladder were conductive, thereby exposing employees to an electrocution hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 A07

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $1989.00 Reduced
29 CFR 1926.1053(a)(7): Ladders shall not be tied or fastened together to provide longer sections unless they are specifically designed for such use.  a. Located at 404 Edinburgh Road in Dublin, Ohio: On or about July 30, 2019 and at times thereto, employees were using a twenty foot Werner aluminum extension ladder to perform painting and install metal fascia cap that had an additional ten foot ladder section ratchet strapped to the top of the ladder in order to extend the ladders working height.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344190483.