Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUNNETCIOGLU RESTAURANTS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUNNETCIOGLU RESTAURANTS LLC in 590 CHARLES ST., PROVIDENCE, RI 02904 (NAICS 722211). OSHA activity number 344198734.

Watch Sunnetcioglu Restaurants LLC — free Get an email when a new federal OSHA severe-injury report for Sunnetcioglu Restaurants LLC is published. One employer, no account, unsubscribe in one click.
Site address
590 CHARLES ST.
City
PROVIDENCE
State
RI
ZIP
02904
Mailing
590 CHARLES ST., PROVIDENCE, RI 02904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
Employees
6
Ownership type
A

4 citations on file for this inspection.

1910.303 B01

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Both kitchens:  On or about 7/31/19 the employer did not ensure that electrical equipment was free from recognized hazards, specifically:    (1) An electrical junction box for a light switch in the upstairs kitchen had a broken cover plate exposing the interior of the box,  (2) A lighted emergency exit sign fixture in the basement was pulled away from the electrical junction box exposing electrical conductors.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2842

1910.303 B02

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling:    (a) Kitchens:  On or about 7-31-19 the employer had not ensured that electrical equipment was being used in accordance with instructions included on the equipment listing, specifically:    1)  an electrical extension cord was observed providing power to a power strip in the upstairs kitchen,    2)  power strips were observed powering power strips at the upstairs register and in the downstairs kitchen.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G01 IV

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    (a) Upstairs kitchen:  On or about 7/31/19 an extension cord was in use supplying power to a power strip in lieu of permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.37 B02

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) Downstairs kitchen:  On or about 7-31-19 the employer did not ensure that the emergency exit was clearly marked by a sign reading "EXIT".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344198734.