MALDEN, MA —
OSHA Inspection: DEYVIN'S CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEYVIN'S CONSTRUCTION, INC. in 60 OLIVER ST., MALDEN, MA 02148 (NAICS 238170). OSHA activity number 344209200.
Where did this inspection happen?
- Establishment
- DEYVIN'S CONSTRUCTION, INC.
- Site address
- 60 OLIVER ST.
- City
- MALDEN
- State
- MA
- ZIP
- 02148
- Mailing
- 118 NEW PARK ST, LYNN, MA 01905
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the competent person did not inspect the ladder-jack scaffold prior to the start of work.
Recent events (2)
- — I (S) $1000
- — Z (S) $3978
1926.451 B05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the employees installing vinyl siding from the elevated platform of the ladder-jack scaffold were exposed to fall hazards posed by the cantilevered ends of the scaffold platform extending more than 18-inches beyond the supports.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the employees accessing the platform of the ladder-jack scaffold via the support ladders were not provided with an adequate means of access.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the employees engaged in installing vinyl siding from the elevated platform of a ladder-jack scaffold were not protected from falling.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 II
- Issued
- Abate by
- Penalty
- Initial $1705.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the open holes located in the driveway work area were not protected by covers.
Recent events (2)
- — I (S) $0
- — Z (S) $1705
1926.1052 C01
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Location - 60 Oliver Street, Malden, MA: On or about 07/22/2019, the interior stairway used by the employee to access the second floor of the house was not equipped with a hand or stair rail on the unprotected side of the stairs exposing employees to falls.
Recent events (2)
- — I (S) $0
- — Z (S) $2273
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source