Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TJM INNOVATIONS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TJM INNOVATIONS in 5519 W. WOOLWORTH AVE, MILWAUKEE, WI 53218 (NAICS 326150). OSHA activity number 344214572.

Watch TJM Innovations — free Get an email when a new federal OSHA severe-injury report for TJM Innovations is published. One employer, no account, unsubscribe in one click.
Establishment
TJM INNOVATIONS
Site address
5519 W. WOOLWORTH AVE
City
MILWAUKEE
State
WI
ZIP
53218
Mailing
5519 W. WOOLWORTH AVE, MILWAUKEE, WI 53218
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
29
Ownership type
A

2 citations on file for this inspection.

1910.146 C02

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3441.00 · Current $0.00 Reduced
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  (a) Continental Rollo-Mixer Mark V: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language that would satisfy the requirement for a sign was not provided to inform affected employees of the hazards associated with entry into this permit required confined space mixer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3441

1910.307 C02 I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5735.00 · Current $0.00 Reduced
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present:  (a) Reticulation room - Reticulatus 3000: On or about August 7, 2019, in the Reticulation room, a Class 1, Zone 1 environment, electrical motors located on the reticulation chamber were not rated for the environment.  This exposed employees to hazards associated with flammable hydrogen gas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5735

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344214572.