MILWAUKEE, WI —
OSHA Inspection: TJM INNOVATIONS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TJM INNOVATIONS in 5519 W. WOOLWORTH AVE, MILWAUKEE, WI 53218 (NAICS 326150). OSHA activity number 344214572.
Where did this inspection happen?
- Establishment
- TJM INNOVATIONS
- Site address
- 5519 W. WOOLWORTH AVE
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53218
- Mailing
- 5519 W. WOOLWORTH AVE, MILWAUKEE, WI 53218
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326150
- Employees
- 29
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $3441.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Continental Rollo-Mixer Mark V: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language that would satisfy the requirement for a sign was not provided to inform affected employees of the hazards associated with entry into this permit required confined space mixer.
Recent events (2)
- — I (S) $0
- — Z (S) $3441
1910.307 C02 I
- Issued
- Abate by
- Penalty
- Initial $5735.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: (a) Reticulation room - Reticulatus 3000: On or about August 7, 2019, in the Reticulation room, a Class 1, Zone 1 environment, electrical motors located on the reticulation chamber were not rated for the environment. This exposed employees to hazards associated with flammable hydrogen gas.
Recent events (2)
- — I (S) $0
- — Z (S) $5735
More inspections in this industry (NAICS 326150)
CORRY, PA—2026-06-25
FXI, INC.
TRION, GA—2026-06-15
FOAM PRODUCTS CORP.
RIDGEWAY, VA—2026-06-15
ATLAS ROOFING CORPORATION
RIDGEWAY, VA—2026-06-15
ATLAS ROOFING CORPORATION
LEXINGTON, KY—2026-06-04
69182 - FOAM DESIGN INC
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC