GREEN BAY, WI —
OSHA Inspection: GYX ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GYX ROOFING, LLC in 2613 GREENBRIER RD., GREEN BAY, WI 54311 (NAICS 238160). OSHA activity number 344218946.
Where did this inspection happen?
- Establishment
- GYX ROOFING, LLC
- Site address
- 2613 GREENBRIER RD.
- City
- GREEN BAY
- State
- WI
- ZIP
- 54311
- Mailing
- 2577 FINGER RD., GREEN BAY, WI 54302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1137.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. On and about August 6, 2019, employees reroofing a single story house were exposed to multiple hazards, including but not limited to, falls, struck by, and electrical when they had not been trained to recognize and avoid or correct hazards or to understand and follow the OSHA Standards that applied to their scope of work.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. On and before August 6, 2019, employees performing roofing work had not been trained to recognize and avoid fall hazards or to understand and follow the OSHA Standards that applied.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards. On and about August 6, 2019, employees using an extension ladder to access and egress the roof of a single story house had not been trained to properly use ladders or understand the OSHA Standards applicable to their scope of work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1137.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On August 6, 2019, employees were exposed to falls while reroofing a single story house without fall protection.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3410.00 · Current $1705.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On August 6, 2019, employees were exposed to falls while accessing and egressing the roof using an extension ladder that did not extend at least 3' above the upper landing.
Recent events (2)
- — I (S) $1705
- — Z (S) $3410
1926.1053 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(3): Ladders shall not be loaded beyond the maximum intended load for which they were built, nor beyond their manufacturer's rated capacity. On August 6, 2019, employees were exposed to falls from an extension ladder while more than one person was climbing down the ladder at the same time.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B20
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(20): When ascending or descending a ladder, the user shall face the ladder. On August 6, 2019, employees were exposed to falls from an extension ladder while descending the ladder while facing away.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 III C
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired. On and about August 6, 2019 employees were exposed to shock hazards at a worksite located at 2613 Greenbrier Rd. Green Bay when damaged extension cords were available for use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344218946.