On , OSHA opened a planned safety inspection of LONE STAR INDUSTRIES, INC. in 1702 SECOND AVE NORTH, NASHVILLE, TN 37208 (NAICS 327320). OSHA activity number 344223136.

Watch Lone Star Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Lone Star Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1702 SECOND AVE NORTH
City
NASHVILLE
State
TN
ZIP
37208
Mailing
1702 SECOND AVE NORTH, NASHVILLE, TN 37208
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
15
Ownership type
A

10 citations on file for this inspection.

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9661.00 · Current $5797.00 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees:  a) On or about August 9, 2019, in the captive barge, employees utilizing a flexible cord set with the outer insulation separated from the plug end were exposed to electrical shock.
Recent events (2)
  • — I (S) $5796.6
  • — Z (S) $9661

1910.303 B02

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:  a) On or about August 9, 2019 on the captive barge employees were exposed to electrical shock from a flexible cord 4-way outlet box termination and the employer did not ensure the equipment was listed and labeled for the installation and use.  b) On or about August 9, 2019 in the maintenance area employees were exposed to electrical shock from a flexible cord 4-way outlet box termination and the employer did not ensure the equipment was listed and labeled for the installation and use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  a) On or about August 9, 2019 in the shop area employees were exposed to electrical hazards and the employer did not ensure five circuit breaker openings and conduit knockout openings were effectively closed in a cabinet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they were not grounded. In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass were not provided with bushings designed for the purpose or did not have smooth, well-rounded surfaces on which the cords may bear:  a) On or about August 9, 2019, in the captive barge's break shack, the employees are exposed to electrical shock and the employer did not ensure faceplates were installed on three (3) outlets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables were used as a substitute for the fixed wiring of a structure:  a) On or about August 9, 2019 on the captive barge employees were exposed to electrical shock from the break shack power supply cable cord and the employer did not ensure flexible cords were not used as a substitute for fixed wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1917.112 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8051.00 · Current $4831.00 Reduced
29 CFR 1917.112(b)(1): Guardrails were not provided at locations where employees were exposed to floor or wall openings or waterside edges, including bridges or gangway-like structures leading to pilings or vessel mooring or berthing installations, which present a hazard of falling more than 4 feet (1.22 m) or into the water, except as specified in paragraph (b)(2) of this section:  a) On or about June 9, 2019 in the maintenance area the employees were exposed to a fall from the mezzanine storage area with a height of 8 foot, 11 inches and the employer did not ensure guardrails were provided at locations where employees were exposed to falling.
Recent events (2)
  • — I (S) $4830.6
  • — Z (S) $8051

1917.152 D01 VII

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $6440.00 · Current $3864.00 Reduced
29 CFR 1917.152(d)(1)(vii): Compressed gas cylinders were not secured upright except when hoisted or carried:  a) On or about August 9, 2019 on the captive barge employees were exposed to struck-by hazards and the employer did not ensure compressed gas cylinders were secured upright.
Recent events (2)
  • — I (S) $3864
  • — Z (S) $6440

1917.152 D01 XVI

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1917.152(d)(1)(xvi): Compressed gas cylinders were not stored so that oxygen cylinders are separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes:  a) On or about August 9, 2019 on the captive barge employees were exposed to fire hazards and the employer did not ensure oxygen cylinders were separated from fuel gas cylinders either by distance of 20 feet or a fire-resistant barrier rated for 30 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 H04

Other-than-serious 6 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.95(h)(4): Audiometric examinations were not administered in a room meeting the requirements listed in Appendix D: "Audiometric Test Rooms.":  a) On or before August 9, 2019 in the terminal conference room employees were provided audiometric testing and the room did not meet the requirements of Appendix D to limit the background sound pressure level.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily were medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user:  a) On or about July 22, 2019 on a transit barge an employee donned an elastomeric air-purifying respirator to enter the barge and the employer did not ensure the employee was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View LONE STAR INDUSTRIES, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344223136.