Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHARK EXCAVATION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SHARK EXCAVATION, LLC in 6484 S. STEELE ST., CENTENNIAL, CO 80121 (NAICS 237110). OSHA activity number 344227244.

Watch Shark Excavation, LLC — free Get an email when a new federal OSHA severe-injury report for Shark Excavation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6484 S. STEELE ST.
City
CENTENNIAL
State
CO
ZIP
80121
Mailing
3840 YORK ST. STE. 210, DENVER, CO 80205
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  a)  On or about August 8, 2019, the employer, Shark Excavation, LLC d/b/a Shark Sewer, did not ensure the excavation was inspected by a competent person so as to determine if a cave-in, from any possible sources, could result and potentially cause injury to an employee.
Recent events (1)
  • — Z (S) $2273

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a)  On or about August 8, 2019, the employer, Shark Excavation, LLC d/b/a Shark Sewer, did not ensure employees were protected from cave-in hazards while engaged in sewer pipe repair operations in an excavation, which measured approximately 8 feet in depth.  The employer was using one shore to protect employees.  This was, however, not adequate as an additional, adjacent side was unprotected and had the potential to cave in.
Recent events (1)
  • — Z (S) $0

1926.652 C02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the jobsite during construction of the protective system:  a)  On or about August 8, 2019, the employer, Shark Excavation, LLC d/b/a Shark Sewer, did not ensure the manufacturers tabulated data was on-site during the construction, installation and use of  protective systems so as to protect employees from cave-in hazards during excavation operations.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344227244.