OSHA Inspection: PETTA ENTERPRISES OF WV, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PETTA ENTERPRISES OF WV, LLC in 38 TECHNOLOGY DRIVE, TRIADELPHIA, WV 26059 (NAICS 562211). OSHA activity number 344229364.

Watch Petta Enterprises OF WV, LLC — free Get an email when a new federal OSHA severe-injury report for Petta Enterprises OF WV, LLC is published. One employer, no account, unsubscribe in one click.
Site address
38 TECHNOLOGY DRIVE
City
TRIADELPHIA
State
WV
ZIP
26059
Mailing
128 STEUBENVILLE AVE, CAMBRIDGE, OH 43725
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562211
Employees
75
Ownership type
A

3 citations on file for this inspection.

1910.146 D03 VI

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9446.00 · Current $8097.00 Reduced
29 CFR 1910.146(d)(3)(vi): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, verifying that conditions in the permit space are accepable for entry throughout the duration of an authorized entry:    (a) Wash Bay - On or about 8/8/19, the employer did not adequately monitor the space to ensure that conditions for entry into a permit required confined space remained acceptable throughout the duration of the entry, exposing employees to chemical and explosion hazards.
Recent events (2)
  • — I (S) $8096.5
  • — Z (S) $9446

1910.146 D05 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(d)(5)(ii): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing or monitoring the permit space as necessary to determine if acceptable entry conditions are being maintained during the course of entry operations:  (a) Wash Bay - On or about 8/8/19, the employer did not adequately monitor the space to ensure that conditions for entry into a permit required confined space remained acceptable throughout the duration of the entry, exposing employees to chemical and explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $0.00 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:  (a) Wash Bay - On or about 8/8/19, the employer did not provide training to all employees performing work in permit required confined spaces, exposing employees to chemical and explosion hazards.