Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRINIDAD BALCAZAR LOPEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRINIDAD BALCAZAR LOPEZ in 5370 CENTRAL COLLEGE RD, WESTERVILLE, OH 43081 (NAICS 238160). OSHA activity number 344248893.

Watch Trinidad Balcazar Lopez — free Get an email when a new federal OSHA severe-injury report for Trinidad Balcazar Lopez is published. One employer, no account, unsubscribe in one click.
Site address
5370 CENTRAL COLLEGE RD
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
1476 ELAINE RD, COLUMBUS, OH 43217
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a. On or about August 15, 2019, the employer failed to maintain a safety and health program to address hazards such as fall protection during roofing activities.
Recent events (1)
  • — Z (S) $3978

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  a. On or about August 15, 2019, the employer failed to instruct each employee in the avoidance of unsafe conditions while performing roofing activities.
Recent events (1)
  • — Z (S) $3978

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. On or about August 15, 2019, employees were performing roofing work on a two story residential home without the use of fall protection, thereby exposing the employees to a fall hazard of more than 20 feet.
Recent events (1)
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344248893.