SPANISH FORT, AL —
OSHA Inspection: K&R VINYL SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of K&R VINYL SIDING in QUAIL HOLLOW TOWNHOMES 6767 SPANIEL DRIVE UNITS 113 - 118, SPANISH FORT, AL 36527 (NAICS 238170). OSHA activity number 344252598.
Where did this inspection happen?
- Establishment
- K&R VINYL SIDING
- Site address
- QUAIL HOLLOW TOWNHOMES 6767 SPANIEL DRIVE UNITS 113 - 118
- City
- SPANISH FORT
- State
- AL
- ZIP
- 36527
- Mailing
- 2145 RED FOX ROAD, MOUNT VERNON, AL 36560
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Units 114-116 (Southside Front of Structure): On or about August 21, 2019, the employer did not ensure that hard hats were used by employee(s) on the ground while worker(s) above approximately fifteen (15) feet on a ladder scaffold were performing vinyl siding installations; exposing employee(s) to struck-by hazards from overhead falling/flying materials and equipment.
Recent events (2)
- — I (S) $1400
- — Z (S) $2273
1926.403 I02 I
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) Units 114-116 (Temporary Power Pedestal Box: 200Amps, 240Volts Service): On or about August 21, 2019, the employer required employees to operate a live electrical panel box without a dead front where unprotected wires and bare connectors were present during construction activities; exposing employee(s) to electrical hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2842
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in AL
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
LOXLEY, AL—2026-07-16
CARLOS CHE
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
BIRMINGHAM, AL—2026-07-14
SCHOLAR CRAFT PRODUCTS, INC.
Source