CHARDON, OH —
OSHA Inspection: PENTAIR WATER FILTRATION COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENTAIR WATER FILTRATION COMPANY in 220 PARK DR., CHARDON, OH 44024 (NAICS 333319). OSHA activity number 344255070.
Where did this inspection happen?
- Establishment
- PENTAIR WATER FILTRATION COMPANY
- Site address
- 220 PARK DR.
- City
- CHARDON
- State
- OH
- ZIP
- 44024
- Mailing
- 220 PARK DR., CHARDON, OH 44024
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333319
- Employees
- 244
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $11934.00 · Current $11934.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: Pentair Water Filtration Company located at 220 Park Dr., Chardon, OH 44024: Although the employer established a program for the control of hazardous energy, it was deficient in that not all of the hazardous energy sources were adequately identified; therefore specificity of written procedures for machinery such as, but not limited to, the RotoGran granulating machine (Model: WO-2236-TB, Serial number HP2236TB0601162WO) was missing. On or about August 19, 2019, employees did not control all hazardous energy such as but not limited to, gravity before performing servicing and maintenance activities. Employees who work within the danger zone while clearing plastic scraps from the rotor blades/knives were exposed to amputation hazards.
Recent events (3)
- — F (O) $11934
- — C (S) $11934
- — Z (S) $11934
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $10229.00 · Current $10229.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about August 19, 2019, annual audits to evaluate the effectiveness of the company's machine specific energy control procedures were not completed as required. Energy sources used at the facility include, but are not limited to; electricity, gravity,hydraulic and pneumatic energy.
Recent events (3)
- — F (O) $10229
- — C (S) $10229
- — Z (S) $10229
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $11934.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Pentair Water Filtration Company located at 220 Park Dr., Chardon, OH 44024: On or about August 19, 2019, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d) and required for the control of the hazardous energy sources such as, but not limited to, gravity were followed before employees conducted activities such as, but not limited to, removing jammed plastic material from the rotor blades/knives of the company's (RotoGran) granulating machinery. Employees were exposed to amputation hazards.
Recent events (3)
- — F (S) $0
- — C (S) $11934
- — Z (S) $11934
More inspections in this industry (NAICS 333319)
DURHAM, NC—2026-06-09
161336 - HYDRO SERVICE - SUPPLIES, INC.
PEQUOT LAKES, MN—2026-05-27
111330 - HYBRID LIGHT SOLUTIONS LLC
MADRAS, OR—2026-04-24
317743831 - KEITH MANUFACTURING CO
DANVILLE, KY—2026-02-25
68888 - ITW FOOD EQUIPMENT GROUP LLC
BELLINGHAM, WA—2025-11-06
WA317988600 - CLARUS FLUID INTELLIGENCE LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344255070.