KINGSTON, NY —
OSHA Inspection: SUSTAINABLE STRUCTURES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUSTAINABLE STRUCTURES, LLC in 17-19 ABEEL ST., KINGSTON, NY 12401 (NAICS 236118). OSHA activity number 344274352.
Where did this inspection happen?
- Establishment
- SUSTAINABLE STRUCTURES, LLC
- Site address
- 17-19 ABEEL ST.
- City
- KINGSTON
- State
- NY
- ZIP
- 12401
- Mailing
- 84 CLIFTON AVE, KINGSTON, NY 12401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) 19 Abeel St. Kingston, NY-On or about August 29, 2019, an employee was working from scaffolding that the footings were not sound, rigid, and capable of supporting the loaded scaffold without settling or displacement, exposing the employee to a fall hazard and a crush by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3978
1926.451 E09 IV
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(9)(iv): The use of cross braces on tubular welded frame scaffolds was not prohibited as a means of access or egress: a) 17-19 Abeel St. Kingston, NY-On or about August 29, 2019 an employee was accessing scaffolding by climbing the cross bracing and exposing himself to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2842
1926.452 C04
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur: a) 17-19 Abeel St. Kingston, NY-On or about August 29, 2019 employees were exposed to scaffolding that were missing pins and were not locked together to prevent uplift, where uplift could occur. This exposed the employee to a crush by and fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2842
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344274352.