MARYSVILLE, OH —
OSHA Inspection: JONATHAN VANEGAS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JONATHAN VANEGAS in 1605 DICKSON, MARYSVILLE, OH 43040 (NAICS 238130). OSHA activity number 344288915.
Where did this inspection happen?
- Establishment
- JONATHAN VANEGAS
- Site address
- 1605 DICKSON
- City
- MARYSVILLE
- State
- OH
- ZIP
- 43040
- Mailing
- 7555 GORDAN CIRCLE, COLUMBUS, OH 43235
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $1591.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a. Located at 1605 Dickson in Marysville, Ohio: On or about September 6, 2019, the employer did not maintain an effective safety and health program to ensure hazards were identified and corrected onsite while employees were performing vinyl siding work.
Recent events (2)
- — I (S) $1591.2
- — Z (S) $3978
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. Located at 1605 Dickson in Marysville, Ohio: On or about September 6, 2019, the employer did not ensure that employees working from a pump jack scaffold onsite installing vinyl siding were trained on the safe use of the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 A01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $1591.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(1): Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a. Located at 1605 Dickson in Marysville, Ohio: On or about September 6, 2019, employees were performing siding work from a pump jack scaffold system. The scaffold platform was extended approximately four foot on one end by strapping a two inch by twelve inch wooden board to the platform and approximately three foot on the other end by strapping an aluminum plank to the platform. The employer did not ensure that the modifications to the scaffold platform were approved and capable of supporting the load applied, thereby exposing employees to an approximately fourteen foot fall hazard.
Recent events (2)
- — I (S) $1591.2
- — Z (S) $3978
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $1591.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. a. Located at 1605 Dickson in Marysville, Ohio: On or about September 6, 2019, the employer did not ensure that a competent person was onsite while the pump jack scaffold was erected that was qualitied to ensure that the scaffold was erected properly. Employees were exposed to fall hazards while working from an unsafe scaffold platform approximately fourteen foot from the ground without effective means of fall protection in place and improper planks attached to the scaffold platform to extend the platform's width.
Recent events (2)
- — I (S) $1591.2
- — Z (S) $3978
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $1591.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a. Located at 1605 Dickson in Marysville, Ohio: On or about September 6, 2019, the employer did not ensure that fall protection was in place to protect employees installing vinyl siding from a pump jack scaffold onsite, thereby exposing employees to an approximately fourteen foot fall hazard.
Recent events (2)
- — I (S) $1591.2
- — Z (S) $3978
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344288915.