Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DON B CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DON B CONSTRUCTION, INC. in 111 N. 16TH ST, MEXICO BEACH, FL 32456 (NAICS 238160). OSHA activity number 344299649.

Watch DON B Construction, INC. — free Get an email when a new federal OSHA severe-injury report for DON B Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 N. 16TH ST
City
MEXICO BEACH
State
FL
ZIP
32456
Mailing
115 1ST AVE N., BARTOW, FL 33830
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 3 exposed
Issued
Penalty
Initial $9282.00 · Current $5569.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section:  a.    On or about September 11, 2019, on the 5:12 pitch roof, 3 roofing employees were exposed to an 18 feet fall hazard from the roof eaves in that they were not protected by a fall protection system.  b.    On or about September 11, 2019, on the south side deck, 3 roofing employees who used the extension ladder from the deck were exposed to an 11 feet fall hazard in that the deck railings had been removed, and the employees were not protected by a fall protection system.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $3978.00 · Current $2387.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a.    On or about September 11, 2019, at the south eave, the roof access ladder extending from the deck to the roof was not extended 3 feet above the roof eave, exposing 3 roofing employees to a 7 feet fall hazard.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1926.1053 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:  a.    On or about September 9, 2019, on the south deck, the area around the base and the top of the roof access ladder from the deck to the roof eave was cluttered by discarded roof tarpaulins and loose roof shingles, creating trip and slip hazards to 3 employees who used the ladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344299649.