2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TPI COMPOSITES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TPI COMPOSITES in 63 WATER STREET, FALL RIVER, MA 02721 (NAICS 326130). OSHA activity number 344314810.

Watch TPI Composites — free Get an email when a new federal OSHA severe-injury report for TPI Composites is published. One employer, no account, unsubscribe in one click.
Establishment
TPI COMPOSITES
Site address
63 WATER STREET
City
FALL RIVER
State
MA
ZIP
02721
Mailing
373 WARREN STREET, WARREN, RI 02885
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326130
Employees
50
Ownership type
A

4 citations on file for this inspection.

1910.106 D04 V

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $4831.00 · Current $2416.00 Reduced
29 CFR 1910.106(d)(4)(v): 29 CFR 1910.106(d)(4)(v):  In every inside storage room there was not one clear aisle maintained at least 3 feet wide.    Flammable Storage Room:    A 3 foot wide aisle was not maintained in the flammable storage room.
Recent events (2)
  • — I (O) $2416
  • — Z (S) $4831

1910.106 E07 I C

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $4831.00 · Current $0.00 Reduced
29 CFR 1910.106(e)(7)(i)(c): 29 CFR 1910.106(e)(7)(I)(c):  Locations where flammable vapor-air mixtures may exist under abnormal conditions and for a distance beyond Division 1 locations were not classified Division 2 according to the requirements of subpart S of this part:    Production Room, Gelcoting Area:    Electrical receptacles near drums containing styrene were not approved for a Class 1 Division 2 location.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4831

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8051.00 · Current $4831.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Worksite:    The employer did not develop lockout tagout procedures for each machine.
Recent events (2)
  • — I (S) $4831
  • — Z (S) $8051

1910.212 A01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $8051.00 · Current $4831.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Maintenance Area:    The unused portion of the blade of the Jet Metal Cutting Bandsaw was not guarded.     Back of the Production Area:    The cutting tool of the CNC router was not guarded. - deleted per Informal settlement
Recent events (2)
  • — I (O) $4831
  • — Z (S) $8051

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344314810.