OSHA Inspection: JKN CONSTRUCTION, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JKN CONSTRUCTION, INC. in 10 AUBURN ST., CONCORD, NH 03301 (NAICS 238160). OSHA activity number 344318985.

Watch JKN Construction, INC. — free Get an email when a new federal OSHA severe-injury report for JKN Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10 AUBURN ST.
City
CONCORD
State
NH
ZIP
03301
Mailing
35 TAYLOR ST., FRAMINGHAM, MA 01702
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2500.00 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    a. Site - Employees were not protected from falls of approximately 25 feet while performing roofing work by both working from the roof without fall protection or with inadequate fall protection.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3978

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a. Site - An Aluminum Ladder used by employees to gain access to and from the roof did not extend above the roofs eave.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2842

1926.1053 B12

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2842.00 · Current $1500.00 Reduced
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:      a. Site - Employees using a metal ladder to gain access to and from the roof were not protected from electrical shocks and burns when the ladder was placed next to the electric service feed that was not insulated where the wires entered the structure.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2842