SCRANTON, PA —
OSHA Inspection: DOMINGUEZ & SONS CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DOMINGUEZ & SONS CONSTRUCTION LLC in 226 PITTSON AVENUE, SCRANTON, PA 18505 (NAICS 238160). OSHA activity number 344332879.
Where did this inspection happen?
- Establishment
- DOMINGUEZ & SONS CONSTRUCTION LLC
- Site address
- 226 PITTSON AVENUE
- City
- SCRANTON
- State
- PA
- ZIP
- 18505
- Mailing
- 1827 PROSPECT STREET, SCRANTON, PA 18505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $1705.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) 226 Pittston Avenue, Scranton, PA: An employee was observed working on the ground cleaning roofing debris and was not protected by a protective helmet while working in areas where there was a possible danger of a head injury from impact, or falling or flying objects, on or about September 25, 2019. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1705
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $1705.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) 226 Pittston Avenue, Scranton, PA: Employees were utilizing an Skilsaw electric circular saw connected to an extension cord that was plugged into a receptacle in the rear of a residential structure without an approved ground fault circuit interrupter for employee personal protection, on or about September 25, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1705
1926.451 G01
- Issued
- Penalty
- Initial $2842.00 · Current $3126.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) 226 Pittston Avenue, Scranton, PA: Employees were not protected from falling while performing roofing construction activities from the platform of a ladder jack scaffold, exposing employees to a nineteen (19) foot fall hazard, observed on or about September 25, 2019. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $3126
- — Z (S) $2842
1926.451 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide: a) 226 Pittston Avenue, Scranton, PA: An employee performed work on a ladder jack scaffold that was equipped with a pine plank that was only 11 1/2 inches wide, on or about September 25, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) 226 Pittston Avenue, Scranton, PA: Employees working from the platform on a ladder jack scaffold which was approximately 18 feet above the ground without an adequate means of access, on or about September 25, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 K05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms shall not be bridged one to another: a) 226 Pittston, Avenue, Scranton, PA: An employee performed work from the platform of a ladder jack scaffold that overlapped another scaffold plank which exposed the employee to a fall of approximately 18 feet, on or about September 25, 2019. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source