Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KONGSBERG PROTECH SYSTEMS USA

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KONGSBERG PROTECH SYSTEMS USA in 210 INDUSTRIAL PARK ROAD, JOHNSTOWN, PA 15904 (NAICS 336992). OSHA activity number 344355011.

Watch Kongsberg Protech Systems USA — free Get an email when a new federal OSHA severe-injury report for Kongsberg Protech Systems USA is published. One employer, no account, unsubscribe in one click.
Site address
210 INDUSTRIAL PARK ROAD
City
JOHNSTOWN
State
PA
ZIP
15904
Mailing
210 INDUSTRIAL PARK ROAD, JOHNSTOWN, PA 15904
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336992
Employees
180
Ownership type
A

4 citations on file for this inspection.

1910.107 E02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5115.00 · Current $3325.00 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift:  a)  Paint Booth #3, on or about October 3, 2019 - The quantity of flammable and/or combustible liquids kept in the vicinity of the spraying operations were not kept at a minimum in that there was a 25 gallon container of waste paint and thinner stored inside of the spray booth.
Recent events (2)
  • — I (S) $3324.75
  • — Z (S) $5115

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5115.00 · Current $3325.00 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   a)  Paint Booth Area, on or about October 3, 2019 - The employer did not ensure that employees use eye protection when exposed to eye hazards from spray painting operations.
Recent events (2)
  • — I (S) $3324.75
  • — Z (S) $5115

1910.147 C04 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a)  In the Facility, on or about October 3, 2019 - The employer did not develop and document energy control procedures at the facility.  Employees at the facility utilize lockout for equipment including but not limited to air valves, panels and disconnect boxes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a)  In the Facility, on or about October 3, 2019 - The employer did not conduct a periodic inspection of the energy control procedures at least annually at the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344355011.