Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TREND SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TREND SERVICES INC. in 16.9 MILES SE DIRECTION FROM ORLA, PECOS, TX 79772 (NAICS 532120). OSHA activity number 344413513.

Watch Trend Services INC. — free Get an email when a new federal OSHA severe-injury report for Trend Services INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TREND SERVICES INC.
Site address
16.9 MILES SE DIRECTION FROM ORLA
City
PECOS
State
TX
ZIP
79772
Mailing
2825 S E EVANGELINE THRUWAY, LAFAYETTE, LA 70508
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
532120
Employees
160
Ownership type
A

3 citations on file for this inspection.

1910.304 G05

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $5205.00 · Current $5205.00
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.  On or about October 23, 2019, Noram Drilling site Rig#30, trailer #796 was not grounded to earth. This condition exposed the employees to electrical shock hazards.
Recent events (1)
  • — Z (S) $5205

1910.305 J02 V

Other-than-serious 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $974.00 · Current $974.00
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered.  On or about October 23, 2019, Noram Drilling site, Rig#30, outdoor receptacles did not have covers and were not protected from the weather. This condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (O) $974

1910.303 B02

Other-than-serious 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $974.00 · Current $974.00
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.   On or about October 23, 2019, Noram Drilling site Rig #30, several extension cords were connected together (daisy-chained) to power the sewage water recovery tanks. Employees were exposed to a fire and electric shock hazards.