Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POWERFOAM, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of POWERFOAM, LLC in 550 MURRAY ST. 287, MIDLOTHIAN, TX 76065 (NAICS 326140). OSHA activity number 344435177.

Watch Powerfoam, LLC — free Get an email when a new federal OSHA severe-injury report for Powerfoam, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
POWERFOAM, LLC
Site address
550 MURRAY ST. 287
City
MIDLOTHIAN
State
TX
ZIP
76065
Mailing
550 MURRAY ST. 287, MIDLOTHIAN, TX 76065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.36 E02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2576.00 · Current $1546.00 Reduced
29 CFR 1910.36(e)(2): At the receiving area, the exit door did not swing out in the direction of exit travel.    In the shipping and receiving room, the employer did not ensure the exit door used by employees as an exit route swung outward in the direction of the exit discharge for quick exit of the building in case of an emergency exposing employees to fire and smoke hazards.
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1932.00 · Current $1159.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   In the shipping and receiving room, the employer did not ensure the exit door used by employees as an exit was equipped or identified with an EXIT sign.  The employees were exposed to fire and smoke hazards.
Recent events (2)
  • — I (S) $1159.2
  • — Z (S) $1932

1910.305 B03 II

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1932.00 · Current $1159.00 Reduced
29 CFR 1910.305(b)(3)(ii): 29 CFR 1910.305(b)(3)(ii): Boxes shall be closed by suitable covers securely fastened in place, boxes were not closed as required.   In the Lamination room on the south wall, the employer did not ensure the electrical panel boxes used to energize the lamination machines, lights and other electrical equipment were effectively closed during operations.  Employees were exposed to electrical shock hazards..
Recent events (2)
  • — I (S) $1159.2
  • — Z (S) $1932

1910.305 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $361.00 · Current $217.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.     In the Lamination room, the employer did not provide strain relief device to prevent tension on the extension cord used to energize the Pelones heater.  The employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (O) $216.6
  • — Z (O) $361

1910.334 A02 I

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).   In the Lamination room, the employees used an Pelone heater and floor fan connected to an extension cord missing the ground pin.  The employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View POWERFOAM, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344435177.