Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALLPRO MANUFACTURING, INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ALLPRO MANUFACTURING, INC in 709 NORTH VELASCO STREET, HOUSTON, TX 77003 (NAICS 331491). OSHA activity number 344440201.

Watch Allpro Manufacturing, INC — free Get an email when a new federal OSHA severe-injury report for Allpro Manufacturing, INC is published. One employer, no account, unsubscribe in one click.
Site address
709 NORTH VELASCO STREET
City
HOUSTON
State
TX
ZIP
77003
Mailing
709 NORTH VELASCO STREET, HOUSTON, TX 77003
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331491
Employees
14
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $2310.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard:      a) At the facility, extruder area: employees were exposed to a struck-by hazard of high pressure hydraulic hose and connection failure on the lead extruder.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $3856

1910.151 C

Other-than-serious 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $0.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) At the facility, maintenance shop: On or about November 8, 2019 employees were exposed to corrosive chemicals when using sodium hydroxide, pH 13-14, without an eye wash readily accessible.      b) At the facility, storage area adjacent to extruder: On or about March 9, 2020 employees were exposed to corrosive material when using Metso Pentabead, containing sodium metasilicate pentahydrate, pH 14, without a suitable facility for flushing of the eyes.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3856

1910.217 D09 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $3238.00 Reduced
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press:    a) At the facility, fabrication shop:  Power Press, 60 ton, Global Precise Machinery Company Ltd., Model: J23-63T, Serial Number 14080001, employees were exposed to amputation hazards when adjusting the die without the use of safety blocks.
Recent events (2)
  • — I (S) $3238
  • — Z (S) $5398

1910.217 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(f)(2): Supervision to ensure that correct operating procedures were being followed on mechanical power press(es) was inadequate:  a) At the facility, fabrication shop:  Power Press, 60 ton, Global Precise Machinery Company Ltd., Model: J23-63T, Serial Number 14080001, where operating procedures to prevent hands and arms from entering the danger zone for adjustments was not followed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Other-than-serious 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $433.00 · Current $260.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    a) At the facility, extruder area: electrical panel 2, there was an open circuit breaker space not covered, exposing the busbar.    b) At the facility, extruder area: Frank W Murphy Inc, Model TR-720730, 480 volt pump control unit, the bottom entry conduit was not secure, exposing insulated conductors.
Recent events (2)
  • — I (O) $260
  • — Z (O) $433

1910.305 B02 I

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $433.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) At the facility, extruder space, west wall: multiple 240/480 volt electrical connection boxes were not equipped with covers, exposing insulated conductors.
Recent events (2)
  • — I (O) $0
  • — Z (O) $433

View ALLPRO MANUFACTURING, INC's full OSHA safety record →