IRVINGTON, NY —
OSHA Inspection: JEFF'S CARPENTRY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JEFF'S CARPENTRY, LLC. in 2 TAXTER RIDGE LANE, IRVINGTON, NY 10533 (NAICS 238170). OSHA activity number 344471222.
Where did this inspection happen?
- Establishment
- JEFF'S CARPENTRY, LLC.
- Site address
- 2 TAXTER RIDGE LANE
- City
- IRVINGTON
- State
- NY
- ZIP
- 10533
- Mailing
- 7 HARRISON STREET, DANBURY, CT 06810
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02
- Issued
- Penalty
- Initial $4048.00 · Current $4048.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: A) Exterior, Right hand side of the house: Employees were exposed to fall/scaffold collapse hazards of approximately 28 feet while working on a pump jack scaffold that was not erected on firm foundation, on or about November 25th 2019.
Recent events (1)
- — Z (S) $4048
1926.451 G01
- Issued
- Penalty
- Initial $4048.00 · Current $4048.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) Exterior, Pump jack scaffold on the right side of the house: Employees were exposed to fall hazards of approximately 28 feet while working on a pump jack scaffold that was not protected by a complete guardrail system (including end rails) or another means of fall protection in place, on or about August 8th, 2019.
Recent events (1)
- — Z (S) $4048
1926.452 J02
- Issued
- Penalty
- Initial $2892.00 · Current $2892.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. A) Exterior, Pump jack scaffold on the right side of the house: Employees were exposed to fall hazards of approximately 28 feet while working on a pump jack scaffold that was not braced at the bottom, on or about November 25th, 2019.
Recent events (1)
- — Z (S) $2892
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344471222.