Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHEFA FOODS NY INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SHEFA FOODS NY INC. in 110 ROUTE 9W, CONGERS, NY 10920 (NAICS 445291). OSHA activity number 344480736.

Watch Shefa Foods NY INC. — free Get an email when a new federal OSHA severe-injury report for Shefa Foods NY INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SHEFA FOODS NY INC.
Site address
110 ROUTE 9W
City
CONGERS
State
NY
ZIP
10920
Mailing
110 ROUTE 9W, CONGERS, NY 10920
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445291
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.263 K05

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3856.00 · Current $2660.00 Reduced
29 CFR 1910.263(k)(5): Reversible dough brakes were not provided with a guard or tripping mechanism on each side of the rolls. These guards shall be so arranged as to stop the machine or reverse the direction of the rolls so that they are outrunning if the guard is moved by contact of the operator.    On or about and times prior to: 11/20/2019    Location: Dough mixing; South West wall     a) The employer did not maintain the dough sheeter's safety guard switch to prevent inadvertent contact with rollers when the safety guards are lifted to stop the machine; exposing employees to caught-in hazard.
Recent events (2)
  • — I (S) $2660
  • — Z (S) $3856

1910.303 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2313.00 · Current $1590.00 Reduced
29 CFR 1910.303(g)(1)(i)(A): The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;    On or about and times prior to: 12/4/2019    Location: 2nd floor, South West wall circuit breaker panel     a) The employer did not keep the area in front of a circuit breaker panel unobstructed exposing employees to an electrical and fire hazard; and preventing de-energization in the case of an abnormal condition.
Recent events (2)
  • — I (S) $1590
  • — Z (S) $2313

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344480736.