ROCHESTER, NY —
OSHA Inspection: TOKENIZE INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TOKENIZE INC. in 4545 EAST RIVER ROAD SUITE 310, ROCHESTER, NY 14623 (NAICS 541512). OSHA activity number 344483599.
Where did this inspection happen?
- Establishment
- TOKENIZE INC.
- Site address
- 4545 EAST RIVER ROAD SUITE 310
- City
- ROCHESTER
- State
- NY
- ZIP
- 14623
- Mailing
- 4545 EAST RIVER ROAD SUITE 310, WEST HENRIETTA, NY 14586
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541512
- Employees
- 22
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $3084.00 · Current $1850.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) On or about 12/14/19, lab employee(s) applying Loctite AA 3942 light curing adhesive known as 3942 light cure medical device. Employee(s) wore a 3M half face elastomeric respirator with organic vapor/P100 cartridges. The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1850
- — Z (S) $3084
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about 12/14/19, lab employee(s) applying Loctite AA 3942 light curing adhesive known as 3942 light cure medical device. Employee(s) wore a 3M half face elastomeric respirator with organic vapor/P100 cartridges. The employer did not provide a medical evaluation to determine employee ability to use a respirator. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2313.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Lab - On or about 12/14/19, a Loctite glue gun, operating at 115 volts and 2.04 amperes, a Hakko power supply for the solder gun, operating at 115 volts and 0.58 amperes, Yihua 8508D air station operating at 115 volts and 8 amperes, and a Hakko FA400 smoke absorber operating at 115 volts and 0.16 amperes were connected to a relocatable power tap, operating at 115 volts and 15 amperes. A relocatable power tap are not intended to be used as a substitute for fixed wiring. The power tap was not used or installed in accordance with instructions included in the listing or labeling. (b) Lab - On or about 12/14/19, a Loctite glue gun, operating at 115 volts and 2.04 amperes, a Hakko power supply for the solder gun, operating at 115 volts and 0.58 amperes, Yihua 8508D air station operating at 115 volts and 8 amperes, and a Hakko FA400 smoke absorber operating at 115 volts and 0.16 amperes were connected to a relocatable power tap, operating at 115 volts and 15 amperes. The power tap was glued to a surface. The power tap was not used or installed in accordance with instructions included in the listing or labeling. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1400
- — Z (S) $2313
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2313.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about 12/4/19, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program. Lab employees use chemicals such as, but not limited to, Loctite AA 3942 light curing adhesive known as 3942 light cure medical device (which contains hazardous chemicals such as isobornyl acrylate and 2-hydroxyethyl methacrylate), Chip Quik SMDSW 0.020 Sn63 Pb37 (which contains hazardous chemicals such as lead), and isopropyl alcohol 91% (a hazardous chemical). A written program should include descriptions of how the criteria for: 1. Labeling and other forms of warning; 2. Safety Data Sheets AND 3. Employee information and training will be met. Additionally, a list of hazardous chemicals known to be present in the workplace must be compiled. Methods used to inform employees of the hazards associated with non routine tasks and the informing of contractors of workplace hazard must also be addressed. The written program must be made available upon request. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1400
- — Z (S) $2313
1910.1200 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with either the information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) On or about 12/14/19, a spray bottle containing 91% isopropyl alcohol, a flammable liquid, was not labeled. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet for each hazardous chemical in use: a) On or about 12/4/19, lab employees use chemicals such as, but not limited to, Loctite AA 3942 light curing adhesive known as 3942 light cure medical device (which contains hazardous chemicals such as isobornyl acrylate and 2-hydroxyethyl methacrylate), Chip Quik SMDSW 0.020 Sn63 Pb37 (which contains hazardous chemicals such as lead), and isopropyl alcohol 91% (a flammable liquid). The employer did not have a safety data sheet for each hazardous chemical in use. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Employees must be informed of: 1. The requirements of this section: 2. Any operations where hazardous chemicals are present; AND 3. The location and availability of the written Hazard Communication Program, list(s) of hazardous chemicals and Safety Data Sheets. Employee training must include at least: 1. Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area. 2. The physical and health hazards of the chemicals in the work area. 3. The measures employees can take to protect themselves such as specific procedures, appropriate work practices, emergency procedures and personal protective equipment to be used. 4. The details of the employers Hazard Communication Program including an explanation of labeling systems, Safety Data Sheets and how employees can obtain and use the appropriate hazard informat a) On or about 12/14/19, lab employees use chemicals such as, but not limited to, Loctite AA 3942 light curing adhesive known as 3942 light cure medical device (which contains hazardous chemicals such as isobornyl acrylate and 2-hydroxyethyl methacrylate), Chip Quik SMDSW 0.020 Sn63 Pb37 (which contains hazardous chemicals such as lead), and isopropyl alcohol 91% (a hazardous chemical). Employees were not provided with effective information and training on hazardous chemicals in their work area. ion. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the safety data sheet, and how employees can obtain and use the appropriate hazard information: a) On or about 12/14/19, lab employees use chemicals such as, but not limited to, Loctite AA 3942 light curing adhesive known as 3942 light cure medical device (which contains hazardous chemicals such as isobornyl acrylate and 2-hydroxyethyl methacrylate), Chip Quik SMDSW 0.020 Sn63 Pb37 (which contains hazardous chemicals such as lead), and isopropyl alcohol 91% (a flammable). Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the safety data sheet, and how employees can obtain and use the appropriate hazard information. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. a) On or about 12/14/19, empty cardboard boxes were stored under tables in the lab. All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.141 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials: a) On or about 12/14/19, lab employees use chemicals such as, but not limited to, Loctite AA 3942 light curing adhesive known as 3942 light cure medical device (which contains hazardous chemicals such as isobornyl acrylate and 2-hydroxyethyl methacrylate), Chip Quik SMDSW 0.020 Sn63 Pb37 (which contains hazardous chemicals such as lead), and isopropyl alcohol 91% (a hazardous chemical). Employees were permitted to consume food or beverage in an area exposed to toxic materials. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1025 L01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) On or about 12/14/19, lab employees solder using Chip Quik SMDSW 0.020 Sn63 Pb37 which contains lead. Employees working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 541512)
SEATTLE, WA—2026-05-20
WA317991319 - EXTRAHOP NETWORKS INC
FORT WORTH, TX—2026-04-23
SIEMENS INC.
ORLANDO, FL—2026-04-15
FLORIDA CONVERSION LLC
HUMBLE, TX—2026-03-18
SAGENET, LLC
JEFFERSONVILLE, OH—2026-01-22
LG CNS AMERICA INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344483599.