Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION STEEL ERECTORS, L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECISION STEEL ERECTORS, L.L.C. in 120 NW 27TH AVE, MIAMI, FL 33135 (NAICS 238120). OSHA activity number 344492483.

Watch Precision Steel Erectors, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Precision Steel Erectors, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
120 NW 27TH AVE
City
MIAMI
State
FL
ZIP
33135
Mailing
2080 S. OCEAN DRIVE UNIT 1206, HALLANDALE BEACH, FL 33009
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
17
Ownership type
A

4 citations on file for this inspection.

1926.752 E

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $3239.00 Reduced
29 CFR 1926.752(e): A site-specific erection plan was not developed by a qualified person and was not available at the work site.   On or about November 26, 2019, and at times prior, at 120 NW 27th AVE, Miami, Florida, 33315, employees were installing metal decking, during which a site-specific erection plan was not developed by a qualified person and was not available at the work site; therefore exposing the employees to fall and delayed rescue/emergency response hazards.     NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $3238.8
  • — Z (S) $5398

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $3239.00 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:  On or about November 26, 2019 and at times prior, at 120 NW 27th AVE, Miami, Florida, 33315, employees were installing metal decking with an unprotected side or edge more than 15 feet (4.6 m) above a lower level and were not protected by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems; therefore exposing the employees to a fall hazard.   NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $3238.8
  • — Z (S) $5398

1926.760 A02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.760(a)(2): Perimeter safety cables were not installed on final interior and exterior perimeters on the floors as soon as the metal decking was installed.  On or about November 26, 2019 and at times prior, at 120 NW 27th AVE, Miami, Florida, 33315, employees were installing metal decking, during which perimeter safety cables were not installed on interior and exterior perimeters of the decks; therefore exposing the employees to fall a fall hazard.   NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.761 B

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761:  On or about November 26, 2019 and at times prior, at 120 NW 27th AVE, Miami, Florida, 33315, employees were installing metal decking, during which the employer did not provide training by a qualified person to each employee in fall hazard recognition, identification and prevention, and the use and operation of fall hazard prevention systems to be used, and the procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used, and the procedures to prevent falls through/into holes and use/limitations of the site-specific erection plan and hoisting, landing and placing of metal decking bundles; therefore exposing the employees to a fall hazard.   NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344492483.