Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHECON CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHECON CORPORATION in 30 LARSEN WAY, N ATTLEBORO, MA 02763 (NAICS 334419). OSHA activity number 344498175.

Watch Checon Corporation — free Get an email when a new federal OSHA severe-injury report for Checon Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CHECON CORPORATION
Site address
30 LARSEN WAY
City
N ATTLEBORO
State
MA
ZIP
02763
Mailing
30 LARSEN WAY, N ATTLEBORO, MA 02763
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
90
Ownership type
A

5 citations on file for this inspection.

1910.133 A01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $0.00 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    Machine Shop:    An employee operating a surface grinder was not wearing safety glasses with sideshields.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4048

1910.212 A01

Serious Gravity 5 7 instances 10 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $6747.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Tapping Room:    A piston pinchpoint of the S11 Screw Insertion Machine was not guarded.     Carbon CNC Room:    The Haas Milling Machine was not guarded.     Welding Area, Main Floor:    The roll pinchpoint of the Schlatter Machine was not guarded.     Slitting Area:    A chain and sprocket wheel pinchpoint of a slitting machine was not guarded.     Cladding Dept. :    The roll pinchpoint of the form rolling line was not guarded.     Main Production Room:    The wobbler shaft of the 4 high rolling mill was not guarded.     Maintenance Room:    The unused part of the blades of the Jet Metal Cutting Saw and the Wells Metal Cutting saw were not guarded. The back side of a wheel of the metal cutting bandsaw was not guarded.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $6747

1910.217 C02 I A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $0.00 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guards:    Press Room:    An opening of the Bruderer Power Press at the parts discharge side was not adequately guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6747

1910.178 Q07

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  Worksite:  The employer did not document forklift inspections.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.  Tool Room:  Drill Presses were not lagged to the floor.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHECON CORPORATION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344498175.