ARCADIA, WI —
OSHA Inspection: BLASCHKO ENTERPRISES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLASCHKO ENTERPRISES, INC. in 625 DETLOFF DRIVE, ARCADIA, WI 54612 (NAICS 323111). OSHA activity number 344518006.
Where did this inspection happen?
- Establishment
- BLASCHKO ENTERPRISES, INC.
- Site address
- 625 DETLOFF DRIVE
- City
- ARCADIA
- State
- WI
- ZIP
- 54612
- Mailing
- P.O. BOX 220, ARCADIA, WI 54612
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 42
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $7570.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Bindery Area, Stringer Machine No. 2; Employee(s) were performing authorized lockout/tagout tasks, including the lubrication of internal oil reservoirs, without adequate training.
Recent events (2)
- — I (S) $0
- — Z (S) $7570
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $4542.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Bindery Area, Stringer Machine No. 2; Energy isolating device(s) were not operated in such a manner as to isolate energy source(s) prior to performing service and/or maintenance work.
Recent events (2)
- — I (S) $4542
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Bindery Area, Stringer Machine No. 2; Lockout or tagout device(s) were not affixed to the energy isolation device(s) by authorized employee(s) prior to performing service and/or maintenance work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $7570.00 · Current $4542.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Bindery Area, Stringer Machine No. 2; Shear point(s) associated with the reciprocating feed mechanism were not adequately guarded. (b) Bindery Area, Stringer Machine No. 2; The vertical needle lever was not adequately guarded as it traveled beyond the protection of the guard during the lever's downward cycle.
Recent events (2)
- — I (S) $4542
- — Z (S) $7570
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $3786.00 · Current $2270.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Press Room; On or about November 19, 2019, an employee utilizing compressed air for cleaning did not have the pressure reduced to less than 30 p.s.i.
Recent events (2)
- — I (S) $2270
- — Z (S) $3786
1910.305 A02 XI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage. Support shall be in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage: (a) Press Room; Flexible power cord(s) for the ink mixing and formulation dispenser were plugged into an unsupported relocatable power tap that was suspended from a wall outlet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BLASCHKO ENTERPRISES, INC.
ARCADIA, WI—2016-08-01 00:00:00
BLASCHKO ENTERPRISES, INC.
View BLASCHKO ENTERPRISES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
MUSKEGON, MI—2026-07-08
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02
INNOTECH LASER
HERMITAGE, PA—2026-07-01
CCL CONTAINER, INC.
GREEN BAY, WI—2026-06-30
CHARTER NEXT GENERATION, INC.
LEHI, UT—2026-06-25
FIVE INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source