Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: GUY METALS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUY METALS, INC. in 1890 GUY METALS DRIVE, HAMMOND, WI 54015 (NAICS 423510). OSHA activity number 344523295.

Watch GUY Metals, INC. — free Get an email when a new federal OSHA severe-injury report for GUY Metals, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GUY METALS, INC.
Site address
1890 GUY METALS DRIVE
City
HAMMOND
State
WI
ZIP
54015
Mailing
1890 GUY METALS DRIVE, HAMMOND, WI 54015
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
70
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7422.00 · Current $4450.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    a) Throughout the production area; The employer did not conduct periodic inspections of the machine specific energy control procedures on at least an annual basis.
Recent events (2)
  • — I (S) $4450
  • — Z (S) $7422

1910.253 B04 III

Serious Gravity 5 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $7422.00 · Current $2975.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    (a) Northwest production area, compressed gas cylinder storage location; A full compressed oxygen cylinder was stored within 4 feet from two full acetylene cylinders.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $7422

1910.333 B02 III A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7422.00 · Current $4450.00 Reduced
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag was not placed on each disconnecting means used to deenergize circuits and equipment on which work is to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section:    (a) North production area; IMEAS No. 1; On or about December 18, 2019, an employee opened the motor control center (MCC) for IMEAS No. 1 to reset a hydraulic thermal switch without affixing a lock and tag to the electrical disconnect.
Recent events (2)
  • — I (S) $4450
  • — Z (S) $7422

1910.303 E

Other-than-serious 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:  (a) North production area; Motor control centers (MCCs) for IMEAS No. 1, IMEAS No. 2 and IMEAS No. 3 were not provided with markings to indicate electrical equipment voltage, current, wattage, and other necessary ratings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View GUY METALS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344523295.