WHEATON, IL —
OSHA Inspection: JUST ROOF REPAIRS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUST ROOF REPAIRS LLC in 1007 N MAIN ST, WHEATON, IL 60187 (NAICS 238160). OSHA activity number 344526694.
Where did this inspection happen?
- Establishment
- JUST ROOF REPAIRS LLC
- Site address
- 1007 N MAIN ST
- City
- WHEATON
- State
- IL
- ZIP
- 60187
- Mailing
- 562 WELCH ST, GILBERTS, IL
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about December 21, 2019, an employee working on the ground below active roofing operations was exposed to overhead struck-by hazards. The employee was not wearing head protection. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about December 21, 2019 employees engaged in residential roofing operations were exposed to struck by hazards while operating pneumatic nail guns without eye protection. Abatement certification is required for this item in accordance with 29 CFR 1903(c).
Recent events (2)
- — I (S) $1000
- — Z (S) $2273
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about December 21, 2019 employees engaged in residential roofing operations approximately 20 feet above grade were exposed to fall hazards. Fall protection was not being utilized. Abatement documentation is required for this item in accordance with 29 CFR 1903(d).
Recent events (2)
- — I (S) $2500
- — Z (S) $3880
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about December 21, 2019 employees engaged in residential roofing operations approximately 20 feet above grade were exposed to fall hazards. Employees had not received training to enable them to recognize and minimize fall hazards on the jobsite. Abatement certification is required for this item in accordance with 1903(c).
Recent events (2)
- — I (S) $0
- — Z (S) $2772
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about December 21, 2019 employees using a ladder to access/egress a roof while engaged in roofing operations were exposed to fall hazards. The extension ladder being used for access to the roof did not extend three feet above the roof eave/landing surface. Abatement certification is required for this item in accordance with 29 CFR 1903(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344526694.