Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAGLE SIDING, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAGLE SIDING, LLC. in 7155 N. PORT WASHINGTON, GLENDALE, WI 53212 (NAICS 238170). OSHA activity number 344535117.

Watch Eagle Siding, LLC. — free Get an email when a new federal OSHA severe-injury report for Eagle Siding, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
EAGLE SIDING, LLC.
Site address
7155 N. PORT WASHINGTON
City
GLENDALE
State
WI
ZIP
53212
Mailing
2422 S. 31ST ST., MILWAUKEE, WI 53210
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2313.00 · Current $1620.00 Reduced
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.    (a) On or about January 02, 2020, the employer did not ensure the competent person was conducting frequent and regular inspections of the job site to ensure fall protection was being worn, that fall protection systems were installed properly, and that job site conditions were maintained safe.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2313

1926.451 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  (a) On or about January 2, 2020, the ladder jack scaffold used for installing siding, was erected less than three (3) feet from the 220 volt electrical power line drop to the structure. This exposed employee(s) working on the scaffold to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2313.00 · Current $1620.00 Reduced
29 CFR 1926.501(b)(1): Each employee(s) engaged in construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.    (a) On or about January 02, 2020, employee(s) installing siding from the flat roof on the east side of the structure were not protected from falling to the lower level. This exposed employee(s} to a fall hazard of approximately eight (8) feet, seven (7) inches.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2313

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1966.00 · Current $1360.00 Reduced
29 CFR 1926.1053(b)(1): Where a portable ladder(s) was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.      (a) On or about January 02,2020, the portable Werner extension ladder erected on the East side of the Structure, and being used for access to the flat roof, did not extend at least three (3) feet above the gabled roof edge, and/or was not secured to the structure when it was not sufficiently extended.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $1966

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344535117.