Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TROIANO WASTE SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TROIANO WASTE SERVICES, INC. in INDUSTRY ROAD, SOUTH PORTLAND, ME 04106 (NAICS 562111). OSHA activity number 344542824.

Watch Troiano Waste Services, INC. — free Get an email when a new federal OSHA severe-injury report for Troiano Waste Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
INDUSTRY ROAD
City
SOUTH PORTLAND
State
ME
ZIP
04106
Mailing
PO BOX 3541, PORTLAND, ME 04104
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
2
Ownership type
A

13 citations on file for this inspection.

1910.37 A04

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $3374.00 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  Welding Shop - Neither of the two sets of lights, designed to provide illumination during a power outage, were working.
Recent events (2)
  • — I (S) $3373.5
  • — Z (S) $6747

1910.37 B06

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $3374.00 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  Welding Shop - Neither of the two exit signs were illuminated.
Recent events (2)
  • — I (S) $3373.5
  • — Z (S) $6747

1910.37 B07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three fourths of an inch (1.9 cm) wide:  Welding Shop - One of the two exit signs was not legible.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $3374.00 Reduced
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not kept in covered containers when not actually in use:    Welding Shop - The Sherwin-Williams Quick Dry Enamel, a Category 2 flammable liquid, was not kept in a covered container when not in use.
Recent events (2)
  • — I (S) $3373.5
  • — Z (S) $6747

1910.107 C06

Serious Gravity 10 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $9446.00 · Current $4723.00 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  Welding Shop - The electrical outlet, on/off light switches, and associated wiring, located in the spraying area, were not explosion proof.
Recent events (2)
  • — I (S) $4723
  • — Z (S) $9446

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $3374.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  Welding Shop - A written respirator program, that included the provisions in 29 CFR 1910.134(c), had not been established nor implemented.
Recent events (2)
  • — I (S) $3373.5
  • — Z (S) $6747

1910.134 E01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Welding Shop - The employer did not provide a medical evaluation to those employees required to wear a respirator during spray painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Welding Shop - Two employees, required to use tight-filling respirators during spray painting operations, were not fit tested prior to initial use of the respirator and as least annually thereafter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  Welding Shop - Respirators with tight-fitting facepieces were worn by employees with full beards that came between the sealing surface of the facepiece and their face.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  Welding Shop - Respirators were not stored in a manner that would protect them from contamination or dust, nor were they stored to prevent deformation of the facepiece and exhalation valve.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k):  The employer did not provide effective and annual training to employees who are required to use respirators:  Welding Shop - The employer did not provide training to those employees required to wear respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $2024.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Welding Shop - Three fire extinguishers were not readily accessible; they were  blocked by various items.
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1910.157 C04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use:  Welding Shop - One fire extinguisher was not in its designated place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344542824.