ELEANOR, WV —
OSHA Inspection: DIAMOND ELECTRIC MANUFACTURING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DIAMOND ELECTRIC MANUFACTURING CORPORATION in STATE ROUTE 62, ELEANOR, WV 25070 (NAICS 335999). OSHA activity number 344549134.
Where did this inspection happen?
- Establishment
- DIAMOND ELECTRIC MANUFACTURING CORPORATION
- Site address
- STATE ROUTE 62
- City
- ELEANOR
- State
- WV
- ZIP
- 25070
- Mailing
- PO BOX 830, ELEANOR, WV 25070
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 230
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $12145.00 · Current $8502.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Diamond Electric: On or about January 3, 2020 and times prior, employees performed repairs on automatic coil assemblies with multiple energy sources such as 87psi pneumatic and 208V electric. The employer had not developed, documented or utilized specific energy control procedures for the equipment, during maintenance or testing activities.
Recent events (2)
- — I (S) $8501.5
- — Z (S) $12145
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about January 9, 2020 and times prior, employees perform servicing and maintenance activities such as equipment repairs. The employer did not perform annual periodic inspections of the energy control program to ensure the requirements of the energy control standards are met.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 335999)
ANDOVER, MA—2026-07-09
VICOR CORPORATION
WILLIAMSBURG, VA—2026-07-07
EATON CORPORATION
FRANKFORT, IL—2026-07-06
QUANTUM TECHNICAL SERVICES INC.
WILLIAMSBURG, VA—2026-06-23
EATON CORPORATION
HUMACAO, PR—2026-06-17
EEMCO LLC
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
PARKERSBURG, WV—2026-07-15
UNKNOWN
VIENNA, WV—2026-07-15
PHOENIX ASSOCIATES, INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344549134.