OSHA Inspection: DIAMOND ELECTRIC MANUFACTURING CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DIAMOND ELECTRIC MANUFACTURING CORPORATION in STATE ROUTE 62, ELEANOR, WV 25070 (NAICS 335999). OSHA activity number 344549134.

Watch Diamond Electric Manufacturing Corporation — free Get an email when a new federal OSHA severe-injury report for Diamond Electric Manufacturing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
STATE ROUTE 62
City
ELEANOR
State
WV
ZIP
25070
Mailing
PO BOX 830, ELEANOR, WV 25070
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
230
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $8502.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Diamond Electric: On or about January 3, 2020 and times prior, employees performed repairs on automatic coil assemblies with multiple energy sources such as 87psi pneumatic and 208V electric. The employer had not developed, documented or utilized specific energy control procedures for the equipment, during maintenance or testing activities.
Recent events (2)
  • — I (S) $8501.5
  • — Z (S) $12145

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) On or about January 9, 2020 and times prior, employees perform servicing and maintenance activities such as equipment repairs.  The employer did not perform annual periodic inspections of the energy control program to ensure the requirements of the energy control standards are met.