Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE SANTOS LEIJA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE SANTOS LEIJA in 911 OAK HILL, ALLEN, TX 75013 (NAICS 238160). OSHA activity number 344558960.

Watch Jose Santos Leija — free Get an email when a new federal OSHA severe-injury report for Jose Santos Leija is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE SANTOS LEIJA
Site address
911 OAK HILL
City
ALLEN
State
TX
ZIP
75013
Mailing
4402 GREENLAND DRIVE, MESQUITE, TX 75150
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2892.00 · Current $0.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:     a)  On or about January 14, 2020, at the single family residential construction site, where employees were exposed to struck-by hazards while working in areas where overhead hazards existed without the use of head protection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2892

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $2024.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    a)  On or about January 14, 2020, at the single-family residential construction site, employees were exposed to fall hazards of more than 6-feet above the ground level below while performing roofing work  without the use of a guardrail system or personal fall arrest system.
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:     a)      On or about January 14, 2020, at the multi-family residential site, where employees were exposed to fall hazards while using an extension ladder that did not extend at least three (3) feet above the landing and was not equipped with a grab rail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4048

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344558960.