PINE BROOK, NJ —
OSHA Inspection: ALVOGEN GROUP INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ALVOGEN GROUP INC. in 10 BLOOMFIELD AVE BUILDING B, PINE BROOK, NJ 07058 (NAICS 325412). OSHA activity number 344568704.
Where did this inspection happen?
- Establishment
- ALVOGEN GROUP INC.
- Site address
- 10 BLOOMFIELD AVE BUILDING B
- City
- PINE BROOK
- State
- NJ
- ZIP
- 07058
- Mailing
- 44 WHIPPANY RD SUITE 300, MORRISTOWN, NJ 07960
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $5783.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Facility The employer did not develop and implement a written respiratory protection program for employees required to wear respirators such as, but not limited to, 3M 8511 and 3M 8271 N95 respirators, while performing pharmaceutical formulation activities. Violation occurred on or about 01/22/2020.
Recent events (2)
- — I (S) $3500
- — Z (S) $5783
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employees using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a) Facility The employer did not provide annual fit tests for employees required to wear filtering facepiece respirators such as, but not limited to, 3M 8210 and 8271 N95 respirators, while performing formulation activities. Violation occurred on or about 01/22/2020.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 325412)
ARECIBO, PR—2026-07-02
ST. JUDE MEDICAL, P.R. LLC
MILLCREEK, UT—2026-07-01
ALIRI USA INC
FREDERICK, MD—2026-06-29
ASTRAZENECA PHARMACEUTICALS LP
NORTH CHICAGO, IL—2026-06-25
ABBVIE INC.
CONGERS, NY—2026-06-25
VITANE PHARMACEUTICALS INCORPORATED
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344568704.