Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRIME TRAILER MANUFACTURING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIME TRAILER MANUFACTURING in 7700 N HWY 6, WACO, TX 76712 (NAICS 336212). OSHA activity number 344568811.

Watch Prime Trailer Manufacturing — free Get an email when a new federal OSHA severe-injury report for Prime Trailer Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
7700 N HWY 6
City
WACO
State
TX
ZIP
76712
Mailing
7700 N HWY 6, WACO, TX 76712
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
47
Ownership type
A

9 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $4588.00 · Current $2500.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about January 16, 2020, and at times prior thereto, in the Cargo Finishing Department and Weld Shop, forklift training did not consist of all of the required elements of operator training, such as, but not limited to, a combination of formal instruction, practical training, and evaluation of the operator's performance, exposing employees to crush-by and/or struck-by hazards.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4588

1910.213 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $4588.00 · Current $2500.00 Reduced
29 CFR 1910.213(d)(1): Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws.    On or about January 16, 2020, in the Cargo Finishing Department, the employer did not ensure the Delta X Unisaw blade was equipped with a guard, exposing employees to potential amputation hazards.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4588

1910.243 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $3441.00 · Current $1000.00 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4).    On or about January 16, 2020, and times prior thereto, in the Weld Shop, the employer did not ensure portable grinders were equipped with safety guards. The employees were exposed to flying debris or struck by hazards during use.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3441

1910.303 B01 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $5735.00 · Current $3000.00 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:      In the Weld Shop, the employer did not ensure portable extension cords with damaged insulation were removed from use and or repaired and safe for use. Employees were exposed to potential electrical shock hazards or injuries.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5735

1910.303 B02

Serious Gravity 1 2 instances 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  The employer did not ensure listed or labeled electrical equipment was used or installed in accordance with instructions included in the listing or labeling. Employees were potentially exposed to electrical shock hazards.     a. In the Weld Shop, a portable extension cord was used with a receptacle spliced into the extension cord to provide an additional receptacle.    b. In the Sand Blasting Booth, the spray nozzle was equipped with an electrical light switch to power the nozzle.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   On or about January 16, 2020, and at times prior thereto, in the weld shop, the employer did not ensure a Miller Welder was connected to flexible cords with strain relief, potentially exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about January 16, 2020, and at times prior thereto, in the weld shop, the employer did not ensure portable fire extinguishers were identified, exposing employees to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about January 16, 2020, and at times prior thereto, in the weld shop, the employer did not ensure that all electrical circuit breakers were marked exposing employees to shock or injury.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): Working space about electric equipment rated 600 volts, nominal, or less was used for storage.  On or about January 16, 2020, and at times prior thereto, in the Weld Shop, the employer did not ensure electrical panels were not blocked, exposing employees to potential electrical shock hazards or injuries.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344568811.