PAGOSA SPRINGS, CO —
OSHA Inspection: DENNISON AUTO GROUP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DENNISON AUTO GROUP, LLC in 1887 EAGLE DR., PAGOSA SPRINGS, CO 81147 (NAICS 811111). OSHA activity number 344575576.
Where did this inspection happen?
- Establishment
- DENNISON AUTO GROUP, LLC
- Site address
- 1887 EAGLE DR.
- City
- PAGOSA SPRINGS
- State
- CO
- ZIP
- 81147
- Mailing
- 1887 EAGLE DR., PAGOSA SPRINGS, CO 81147
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 7
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $5398.00 · Current $2700.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system: (a) On or about January 22, 2020, and at times prior, employees were exposed to fall hazards when working on the unguarded loft above the tire wash station, which was 8 feet 2 inches above the concrete floor. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2700
- — Z (S) $5398
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $5398.00 · Current $2700.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) On or about January 11, 2020, and at times prior, employees working in the automotive shop who exposed to eye injury were not required to use eye protection. Eye injury hazards in the area include but are not limited to flying debris, equipment under tension that is disassembled, compressed air, and chemicals including solvents (eye irritant), carburetor and choke cleaner (temporary eye injury), non-chlorinated brake cleaner (serious eye irritant), and battery acid (corrosive). Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2700
- — Z (S) $5398
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2024.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) On or about January 22, 2020, and at times prior employees were exposed to explosion and fire hazards in the north west automotive bay, from the oxygen and acetylene tanks that were stored together. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2024
- — Z (S) $4048
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2024.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) On or about January 22, 2020, and at times prior, employees were exposed to contact with live electrical conductors while plugging in and unplugging equipment on the outlet mounted to the east post of the BendPak auto lift. The energized outlet was broken and open such that fingers could reach inside the box. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2024
- — Z (S) $4048
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) On or about January 22, 2020, and at times prior, employees were exposed to eye injury from corrosive chemicals while handling automotive batteries, and did not have access to an eye wash station. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) On or about January 22, 2020, and at times prior, employees were exposed to electrical hazards in that the employer did not ensure that the electrical panel on the north wall of the machine shop was labeled. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about January 22, 2020, and at times prior, employees were exposed to fire, and electrical hazards from cardboard and other items stored in front of electrical panel on the north wall of the shop. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present, using a product identifier that was referenced on the appropriate safety data sheet: (a) On or about January 22, 2020, and at times prior, employees using hazardous chemicals did not have access to a list of hazardous chemicals that are used in the workplace with all of the required information to facilitate recognition of the corresponding Safety Data Sheet, as needed by the exposed worker. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about, was introduced into their work area: (a) On or about January 22, 2020, and at times prior, employees were exposed to hazardous chemicals without having been trained on the chemicals, the hazards, labels, proper handling and personal protective equipment, and how to respond incase of an incident with the chemicals. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
MANASSAS, VA—2026-07-15
VAFMC LLC
NORFOLK, VA—2026-07-15
CITY OF NORFOLK DEPT OF GENERAL SERVICES DIVISION OF FLEET MANAGEMENT
ENOLA, PA—2026-07-15
ENOLA AUTO SALES
LYNCHBURG, TN—2026-07-14
MOORE COUNTY SCHOOLS - BUS GARAGE
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344575576.