Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: WHEATON GRAIN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WHEATON GRAIN, INC. in 5852 COUNTY HWY T, CHIPPEWA FALLS, WI 54729 (NAICS 424510). OSHA activity number 344593710.

Watch Wheaton Grain, INC. — free Get an email when a new federal OSHA severe-injury report for Wheaton Grain, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WHEATON GRAIN, INC.
Site address
5852 COUNTY HWY T
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
5852 COUNTY HWY T, CHIPPEWA FALLS, WI 54729
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
4
Ownership type
A

6 citations on file for this inspection.

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3470.00 · Current $2082.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) GSI grain dryer; On or about the week of January 6, 2020, the employer did not ensure the grain dryer was isolated from its natural gas fuel supply during servicing activities of cleaning out the dryer.
Recent events (2)
  • — I (S) $2082
  • — Z (S) $3470

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) GSI grain dryer; On or about the week of January 6, 2020, the employer did not ensure that lockout devices were affixed to the grain dryer's isolation point for natural gas during servicing activities of cleaning out the dryer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 II D

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:    (a) GSI grain dryer; On or about the week of January 6, 2020, the employer did not ensure that each authorized employee involved in cleaning out the dryer affixed their own lockout lock on isolation points for electrical and natural gas energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 M04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(m)(4): The employer did not implement procedures in the grain handling facility for the use of tags and locks which would prevent the inadvertent application of energy or motion to equipment being repaired, serviced, or adjusted, which could result in employee injury:    (a) Throughout the facility; The written lockout procedure for a GSI brand grain dryer did not identify the location of and specific steps for isolating and locking out the natural gas valve or overhead gates from the feed legs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1735.00 · Current $1041.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Dryer shack; Two circuit breaker openings in an energized 200 Amp circuit breaker panel were not filled or covered.
Recent events (2)
  • — I (S) $1041
  • — Z (S) $1735

1910.272 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(e)(1): The employer did not provide training to employees at least annually and when changes in job assignments would expose them to new hazards in the grain handling facilities:    (a) Throughout the facility; Annual training was not provided to inform employee of general safety precautions for the facility, the facility emergency action plan, dust accumulations hazards, common ignitions sources, preventative maintenance procedures, lockout/tagout procedures, and bin entry procedures.
Recent events (3)
  • — P (O) $0
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344593710.