LA PRYOR, TX —
OSHA Inspection: TORRES READY MIX
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TORRES READY MIX in COUNTY ROAD 4008, LA PRYOR, TX 78872 (NAICS 212321). OSHA activity number 344599436.
Where did this inspection happen?
- Establishment
- TORRES READY MIX
- Site address
- COUNTY ROAD 4008
- City
- LA PRYOR
- State
- TX
- ZIP
- 78872
- Mailing
- 154 CO ROAD 4603, DILLEY, TX 78017
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 212321
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.180 D03
- Issued
- Abate by
- Penalty
- Initial $4626.00 · Current $4626.00
General-duty citation text
29 CFR 1910.180(d)(3): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(2)(i) with a determination made as to whether deficiencies constituted a safety hazard: At the yard: On or about January 31, 2020, and at times prior thereto, employees were exposed to a struck-by hazard, while operating a Link-Belt Crane (Model LS-5800) without ensuring frequent inspections, daily to month intervals, were performed to identify items such as, but not limited to, a hydraulic leak on the operator arm, missing windshield and electrical cover, and bent rungs.
Recent events (1)
- — Z (S) $4626
1910.180 D04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard: At the yard: On or about January 31, 2020, and at times prior thereto, employees were exposed to a struck-by hazard, while operating a Link-Belt Crane (Model LS-5800) without ensuring periodic inspections, monthly to yearly intervals, were performed to identify items such as, but not limited to, a hydraulic leak on the operator arm, missing windshield and electrical cover, and bent rungs.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 212321)
SAN JUAN, PR—2026-07-10
PROYECTO ENLACE
RIALTO, CA—2026-07-07
CEMEX CONSTRUCTION MATERIALS PACIFIC, LLC
CHICO, CA—2026-07-06
7/11 MATERIALS, INC.
PLEASANTON, CA—2026-07-02
CALMAT CO.
HUNTINGTON BEACH, CA—2026-06-30
TIM GREENLEAF ENGINEERING
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344599436.