2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SURFACE FINISH TECHONOLOGIES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SURFACE FINISH TECHONOLOGIES, INC. in 215 JUDSON STREET, ELMIRA, NY 14901 (NAICS 332813). OSHA activity number 344626767.

Watch Surface Finish Techonologies, INC. — free Get an email when a new federal OSHA severe-injury report for Surface Finish Techonologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
215 JUDSON STREET
City
ELMIRA
State
NY
ZIP
14901
Mailing
215 JUDSON STREET, ELMIRA, NY 14901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
48
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 4 instances 3 exposed
Issued
Penalty
Initial $4048.00 · Current $2631.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the lifting devices fail:    a)  Anodize Area, on or about 2/11/2020: A 1 ton CM Loadstar Hoist No. 9 had not been inspected on a frequent and periodic basis.    b) Zinc-Nickel Area, on or about 2/11/2020: A 1/2 ton CM Loadstar Hoist No. 3 had not been inspected on a frequent and periodic basis.    c) Eastside Oxide Area, on or about 2/11/2020: A 1/2 ton CM Loadstar Hoist No. 7 had not been inspected on a frequent and periodic basis.    d) CAD Plating Area, on or about 2/11/2020: A 250 lb CM Shopstar Hoist No. 75 had not been inspected on a frequent and periodic basis.
Recent events (2)
  • — I (S) $2631.2
  • — Z (S) $4048

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(ii): The employer had not certified that periodic inspections of the energy control procedures had been performed:   a) At the establishment, on or about 2/11/2020: Certification that periodic inspections had been accomplished on the energy control procedures for employees performing servicing and/or maintenance on various equipment, including but not  limited to:  Quincey Small Baking Oven; Grieve Big Oven; Big Steam Boiler; Hot Water Boiler; Small Steam Process Boiler Air Compressors #1 and #3; Air Dryer #1; Roof Top Generator and Chiller had not been completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344626767.