Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ZDS CONSTRUCTION CORP

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ZDS CONSTRUCTION CORP in 31 VENETIAN WAY, MIAMI BEACH, FL 33139 (NAICS 238130). OSHA activity number 344628383.

Watch ZDS Construction Corp — free Get an email when a new federal OSHA severe-injury report for ZDS Construction Corp is published. One employer, no account, unsubscribe in one click.
Site address
31 VENETIAN WAY
City
MIAMI BEACH
State
FL
ZIP
33139
Mailing
3307 NW 7TH ST, MIAMI, FL 33125
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
30
Ownership type
A

6 citations on file for this inspection.

1926.501 B04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $13494.00 · Current $10795.00 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers:    On or about 2/6/2020, at the construction site located at 31 Venetian Way, Miami Beach, FL 33139.  Parking garage, 3rd floor, south side - Employees were exposed to a fall hazard of 9'-4" while working on, near or around a floor opening measuring 3'-0" x 3'-1", which was not covered.
Recent events (2)
  • — I (S) $10795.2
  • — Z (S) $13494

1926.502 I03

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $12145.00 · Current $6073.00 Reduced
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:    On or about 2/12/2020, at the construction site located at 31 Venetian Way, Miami Beach, FL 33139.  Parking garage, 3rd floor, north side - Employees were exposed to a fall hazard of 9'-4" while working on, near or around a floor opening measuring 24" x 36", which was covered with an unsecured plywood.
Recent events (2)
  • — I (S) $6072.5
  • — Z (S) $12145

1926.502 I04

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  On or about 2/12/2020, at the construction site located at 31 Venetian Way, Miami Beach, FL 33139. Parking garage, 3rd floor, north side - Employees were exposed to a fall hazard of 9'-4" while working on, near or around a floor opening measuring 24" x 36", which was covered with an unmarked plywood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8676.00 · Current $4338.00 Reduced
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye:    On or about 2/6/2020, at the construction site located at 31 Venetian Way, Miami Beach, FL 33139, the employer did not report a hospitalization of an employee due to a work related accident.
Recent events (2)
  • — I (O) $4338
  • — Z (O) $8676

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  On or about 2/20/2020, at the construction site located at 31 Venetian Way, Miami Beach, FL 33139. 4th floor, Building B - An employee was exposed to an electrical shock hazard while energizing a portable power tool using an extension cord that lacked a ground prong on its attachment plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 B02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy.  On or about 2/12/2020, at  the construction site located at 31 Venetian Way, Miami Beach, FL 33139. Building B, 3rd floor, an employee was exposed to the risk of receiving electrical shock while energizing a tool (i.e. tool used for cutting cables) from an outlet that lacked a coverplate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344628383.