THORNVILLE, OH —
OSHA Inspection: ECO-SEAL HOME SOLUTIONS
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of ECO-SEAL HOME SOLUTIONS in 9975 HONDA HILLS ROAD, THORNVILLE, OH 43076 (NAICS 238910). OSHA activity number 344632294.
Where did this inspection happen?
- Establishment
- ECO-SEAL HOME SOLUTIONS
- Site address
- 9975 HONDA HILLS ROAD
- City
- THORNVILLE
- State
- OH
- ZIP
- 43076
- Mailing
- 6710 COUNTY ROAD 624, MILLERSBURG, OH 44654
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 32
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $9445.00 · Current $9445.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a. Located at 9975 Honda Hills Road in Thornville, Ohio: On or about February 17, 2020, the employer did not instruct and train employees performing trenching work onsite on the recognition of cave-in hazards and the protective systems requirements to prevent cave-in hazards in accordance with 29 CFR 1926 Subpart P.
Recent events (2)
- — I (S) $9445
- — Z (S) $9445
1926.416 A01
- Issued
- Penalty
- Initial $6748.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. a. Located at 9975 Honda Hills Road in Thornville, Ohio: On or about February 17, 2020, the employer did not ensure that employees performing trenching work across the driveway were protected from electrical shock hazards due to an energized 220 volt underground electrical circuit that ran across the trench area.
Recent events (2)
- — I (S) $0
- — Z (S) $6748
1926.651 J02
- Issued
- Penalty
- Initial $9445.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a. Located at 9975 Honda Hills Road in Thornville, Ohio: On or about February 17, 2020, employees working inside the trench installing drainage pipe were not protected from a soil pile placed within two foot from the trench wall, thereby exposing employees to struck by and crushed by hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $9445
1926.651 K01
- Issued
- Penalty
- Initial $9445.00 · Current $9445.00
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. a. Located at 9975 Honda Hills Road in Thornville, Ohio: On or about February 17, 2020, the employer did not ensure that the trench was inspected by a competent person to identify possible cave-in hazards and to ensure that adequate protective systems were in place prior to permitting employees to perform work within the trench.
Recent events (2)
- — I (S) $9445
- — Z (S) $9445
1926.652 A01
- Issued
- Penalty
- Initial $9445.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section. a. Located at 9975 Honda Hills Road in Thornville, Ohio: On or about February 17, 2020, the employer did not ensure that a protective system was in place to prevent cave-in hazards for employees performing work in the trench, thereby exposing employees to a crushed by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $9445
More inspections in this industry (NAICS 238910)
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
COLLINSVILLE, IL—2026-07-14
L W CONTRACTORS, INC.
STAUNTON, VA—2026-07-14
BRIERY BRANCH LAND MANAGEMENT LLC
BEND, OR—2026-07-14
317744769 - K & E EXCAVATING INC
MIDDLETOWN, NY—2026-07-14
MC STEEL, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344632294.