Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXPRESS WELL SERVICE & SUPPLY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXPRESS WELL SERVICE & SUPPLY, INC. in 1110 US HWY 40, VICTORIA, KS 67671 (NAICS 213112). OSHA activity number 344634019.

Watch Express Well Service & Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Express Well Service & Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1110 US HWY 40
City
VICTORIA
State
KS
ZIP
67671
Mailing
P.O. BOX 19, VICTORIA, KS 67671
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $4048.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  Employees were exposed to struck-by hazards.  Employees engaged in material handing activities using the K-D Manitou forklift, truck model M230CP, serial number M2300452, were exposed to struck-by hazards in that the employer did not provide comprehensive forklift training prior to permitting employees to operate forklifts.
Recent events (2)
  • — I (S) $4048.2
  • — Z (S) $6747

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  Employees were exposed to struck-by hazards.  Employees engaged in material handing activities using the K-D Manitou forklift, truck model M230CP, serial number M2300452, were exposed to struck-by hazards in that employer did not conduct an evaluation of each forklift operator at least once every three years.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $4048.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  Employees were exposed to caught-in and struck-by hazards.  Employees engaged in fabrication activities in the shop area were exposed to caught-in and struck-by hazards in that machine guarding was not provided in the following instances:   a) Powermatic drill press, model number 1200, serial number 520VO575   b )Brilliant Metal cut off saw
Recent events (2)
  • — I (S) $4048.2
  • — Z (S) $6747

1910.213 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $0.00 Reduced
29 CFR 1910.213(b)(1): Woodworking machine was not provided with mechanical or electrical power controls so located that the operator could cut off the power from the machine without leaving his position at the point of operation:  Employees were exposed to caught-in hazard.  Employees working in the garage shop area were exposed to caught-in hazards in that the Brilliant metal cut off saw used to cut wood did not provide a mechanical control so the operator could cut off power without leaving the position at the point of operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6747

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6747.00 · Current $4048.00 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:  Employees were exposed to electrical shock hazard.  Employees engaged in welding activities in the shop area were exposed to electrical shock hazards in that the Miller arc welder, model Millermatic 252 cables had damaged insulation, exposing bare conductors.  The welder was located in the shop area, Eastside wall, and by the walkway door.
Recent events (2)
  • — I (S) $4048.2
  • — Z (S) $6747

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344634019.