Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMBRIZ EXTERIORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMBRIZ EXTERIORS, INC. in 748 GREENWOOD AVE., GLENCOE, IL 60022 (NAICS 238160). OSHA activity number 344652409.

Watch Ambriz Exteriors, INC. — free Get an email when a new federal OSHA severe-injury report for Ambriz Exteriors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
748 GREENWOOD AVE.
City
GLENCOE
State
IL
ZIP
60022
Mailing
542 N. RAVINE DRIVE, ROUND LAKE PARK, IL 60073
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $325.00 · Current $325.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Ambriz Exteriors, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                01                                   03/04/2020 01                                02                                   03/04/2020 01                                03a                                   03/04/2020 01                                03b                                   03/04/2020 01                                04                                  03/04/2020 02                                01                                   03/04/2020   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $325

1926.300 B02

Serious Gravity 5 7 instances 7 exposed
Issued
Abate by
Penalty
Initial $2313.00 · Current $2313.00
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded:       a) On or about February 25, 2020, employees were exposed to rotating parts on a gas operated air compressor motor where the recoil assembly guard was detached from the machine.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2313

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:          a) On or about February 25, 2020, employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 19 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.501 B13

Serious Gravity 10 7 instances 7 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):        a) On or about February 25, 2020, employees were exposed to the hazard of falling while working without fall protection from a pitched roof having a ground to eave height of approximately 21 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:          a) On or about February 25, 2020, employees were exposed to the hazard of falling approximately 19 feet while working from ladder jack scaffolding without the benefit of fall protection.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.1053 B22

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall:              a) On or about February 25, 2020, employees were exposed to the hazard of falling from elevations up to approximately 21 feet when climbing a portable ladder while carrying materials to a pitched roof deck landing surface.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:       a) On or about February 25, 2020, a ridge anchor used as part of a fall protection system was not connected completely to the ridge to ensure the device would be capable of supporting at least 5,000 pounds of force.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

View AMBRIZ EXTERIORS, INC.'s full OSHA safety record →