OSHA Inspection: SPECIAL ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPECIAL ROOFING in CORNER OF 21ST AND BOSTON, TULSA, OK 74112 (NAICS 238160). OSHA activity number 344653381.

Watch Special Roofing — free Get an email when a new federal OSHA severe-injury report for Special Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
SPECIAL ROOFING
Site address
CORNER OF 21ST AND BOSTON
City
TULSA
State
OK
ZIP
74112
Mailing
8720 E. 13TH STREET, TULSA, OK 74112
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $2429.00 Reduced
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were other provisions of paragraph (b) of this section used to provide an alternative fall protection measure:    On or about February 18, 2020, at an apartment complex re-roofing site located on the corner of 21st and Boston in Tulsa, OK, the employer did not ensure that employees, performing roofing work activities from a roof, were in use of fall protection.  This exposed the employees to a fall hazard greater than six(6) feet to the ground below.
Recent events (2)
  • — I (S) $2428.8
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2892.00 · Current $1735.00 Reduced
29 CFR 1926.1053(b)(1):  A portable ladder used for access to an upper landing surface did not have the ladder side rails extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension is not possible because of the ladder's length was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, was not provided to assist employees in mounting and dismounting the ladder.      On or about February 18, 2020, at an apartment complex re-roofing site located on the corner of 21st and Boston in Tulsa, OK, the employer did not ensure that the side rails of an extension ladder extended at least three (3) feet above the landing.  Employees used this ladder to access the roof and were exposed to a fall hazard.