NORTH BABYLON, NY —
OSHA Inspection: BERTOGLIO HOME IMPROVEMENT, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BERTOGLIO HOME IMPROVEMENT, INC. in 766-768 DEER PARK, NORTH BABYLON, NY 11703 (NAICS 238160). OSHA activity number 344658018.
Where did this inspection happen?
- Establishment
- BERTOGLIO HOME IMPROVEMENT, INC.
- Site address
- 766-768 DEER PARK
- City
- NORTH BABYLON
- State
- NY
- ZIP
- 11703
- Mailing
- 1840 HEMPSTEAD TURNPIKE, EAST MEADOW, NY 11554
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4048.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 766-768 Deer Park Avenue, North Babylon, New York - Employees were performing roofing work along the sides and edges of a residential building approximately 11-feet above the ground and did not have fall protection; on or about 02/27/2020. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (3)
- — F (S) $1500
- — C (S) $4048
- — Z (S) $4048
1926.1053 B01
- Issued
- Penalty
- Initial $2892.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite, 766-768 Deer Park Avenue, North Babylon, New York - Employees were using a 16-foot Werner fiberglass extension ladder to access the roof of the residential building approximately 11-feet above the ground. The side rails of the ladder was approximately 12-inches above the landing zone; on or about 02/27/2020. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (3)
- — F (S) $1500
- — C (S) $2892
- — Z (S) $2892
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344658018.