1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WILLERT HOME PRODUCTS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WILLERT HOME PRODUCTS, INC. in 100 21ST STREET, KENOVA, WV 25530 (NAICS 325320). OSHA activity number 344666599.

Watch Willert Home Products, INC. — free Get an email when a new federal OSHA severe-injury report for Willert Home Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 21ST STREET
City
KENOVA
State
WV
ZIP
25530
Mailing
P.O. BOX 386, KENOVA, WV 25530
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325320
Employees
72
Ownership type
A

4 citations on file for this inspection.

1910.252 A02 III B

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $4916.00 · Current $2950.00 Reduced
29 CFR 1910.252(a)(2)(iii)(B): The employer did not ensure that assigned fire watchers were trained in the fire extinguishing equipment made available:    (a)    On or about March 2, 2020 the employer did not ensure that maintenance employees that are assigned as fire watches during hot work activities around flammable solids were trained in the portable fire extinguishers made available.
Recent events (2)
  • — I (S) $2950
  • — Z (S) $4916

1910.29 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $8193.00 · Current $4915.00 Reduced
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface:    (a)    Production Area:  On or about July 21, 2020 employees were not protected from a fall hazard by a standard height railing of a minimum of 39 inches high while standing on portable platforms located on the top platform of the hopper that feeds powdered naphthalene to the ball presses.  The guardrail height was reduced to 32 inches high while standing on the portable platforms.
Recent events (2)
  • — I (S) $4915
  • — Z (S) $8193

1910.305 G01 IV A

Other-than-serious 2 instances 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a)  Production Room next to Ball Presses:  On or about July 21, 2020 an Airmaster floor fan was plugged in on a continuous basis using an extension cord as a substitute for the fixed wiring of the building.  (b)  Production Room next to Debagger Operation:  On or about July 21, 2020 an Airmaster floor fan was plugged in on a continuous basis using an extension cord as a substitute for the fixed wiring of the building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a)    Production Area:    On or about March 2, 2020 the employer had not determined the exposure level of employees that are exposed to naphthalene after the process was changed from using liquid naphthalene to solid naphthalene.